Installation Instructions

Red Slip-on Connectors

A) Strip the over braid back 3 1/2". Be careful not to nick the wires.

B) Shrink a piece of 1" heat shrink over the cut portion of the over braid.

C) Split the two wires back 3". Be careful not to nick the wires.

D) Strip each wire and double the wires over. These wires must be doubled over.

E) Place a male connector on the red wire and a female connector on the yellow wire. Double crimp these

connectors. A good crimp is very important. Poor crimps will cause jumpy readings and are the biggest

source of problems.

Yellow Precision Connector

A) Strip the over braid back 1". Be careful not to nick the wires. Shrink a piece of 1" heat shrink over the

cut portion of the over braid.

B) Remove the yellow cap on the Precision Female Connector.

C) Strip the insulation from the wires back 1/2".

D) Connect the yellow lead of the Extension Cable to the terminal marked “+” and the red lead to the other

terminal. The insulation on these wires should almost touch the mounting screws. Replace the yellow cap

22

Double the wires.

Double Crimp

Keep the tab straight.

Red Slip-on Connector

Male Connector

10. Route Each Extension Cable