10. Route Each Extension Cable

on the Female Precision Connector. Be careful not to overtighten any screws or twist the wires when install-

ing the connector.

Installation Instructions

Plug each probe into its associated Extension Cable. Be sure the connectors mate properly. When tie

wrapping these cables down, be sure there is no strain or pull on the cable against the probe or connectors.

Dress each cable up to the instrument keeping them away from any hot areas such as exhaust stacks, cylinder

heads, etc.

Tie off any excess cable under the instrument panel. Be sure these cables do not obstruct the freedom of

travel of any controls.

11. Hook Up Connecting Wires:

Connect the red wire in the Connecting Wire Harness to the 12 or 24 volt bus via a 1 amp fuse or circuit

breaker (see the Wiring Diagram at the back of this manual). Connect the black wire to ground. Connect the

white/brown to the 12V bus (leave it open for a 24V system). Connect the white/red wire to the 24V bus

(connect it to ground for a 12V system). Connect the white/orange wire to the Panel Light Rheostat.

Tie off any excess cable under the instrument panel. Be sure these cables do not obstruct the freedom of

travel of any controls.

12. Instrument Installation:

Install the instrument from behind the instrument panel using 6 x 32 screws supplied in the accessory kit.

DO NOT USE SCREWS LONGER THAN 1/2".

If this instrument is to be mounted directly under a speaker you will need to install a magnetic shield. This

is a U shaped piece of steel sheet metal. Contact E.I. Inc. for details.