Note:

Although "A" type Axis Units (AXIS-203A, for example) accomodate the same nutrunners as
their older style counterparts, they are not fully interchangeable. REPLACE OLDER STYLE
AXIS UNITS WITH THE SAME, AND REPLACE THE "A" TYPE UNITS WITH OTHER "A"
TYPE UNITS. If it is necessary to intermix older style Units with "A" type Units, contact FEC
INC. for guidance.

AXIS-210 / 205A

DFT-502M4-S/O

AXIS-205 / 205A

DFT-302M3-S/O

AXIS-205 / 205A

DFT-202M3-S/O

AXIS-205 / 205A

DFT-152M3-S/O

AXIS-205 / 205A

DFT-132M3-S/O

AXIS-205 / 205A

DFT-801M3-S/O

AXIS-205 / 205A

DFT-601M3-S/O

AXIS-203 / 203A

DFT-401M2-S/O

AXIS-203 / 203A

DFT-401M1-S/O

AXIS-203 / 203A

DFT-201M1-S/O

AXIS-203 / 203A

DFT-101M1-S1/O1

AXIS UNIT

TOOL TYPE

1. Verify the enclosure power is off. Ensure all cables connected to the front of the Axis Unit

are clearly marked (for reconnection).

2. Disconnect all cables from the front of the Unit.

3. Loosen (do not remove) the four (4) screws that secure the Axis Unit to the back panel.

The upper bracket of the Axis Unit has two slotted holes, and the bottom bracket has two
open-ended slots.

4. Lift up and out on the Axis Unit to remove.

5. Verify the Axis Unit dip switches are set to the appropriate spindle number and ramp-up

time. Refer to Section 4.9.

6. Verify the Axis Units have the same configuration (hardware and software).

7. Install the new Axis Unit in reverse order of removal.

8. Apply power to the enclosure. After approximately 30 seconds, the System will finalize the

Power On Self Test (POST) and the downloading of preset data, and the Axis Unit will
display the spindle number in accordance with the dip switch setting.

Chapter 8: Maintenance and Inspection

User Console Version A3.53

Page 8-15