8.3

Replacements

WARNING:

DO NOT CONNECT OR DISCONNECT CABLES OR OTHER SYSTEM

COMPONENTS WITH POWER APPLIED. FOLLOW LOCKOUT/TAGOUT AND
OTHER APPLICABLE SAFETY PRECAUTIONS WHEN CONNECTING OR

DISCONNECTING CABLING, WIRING, AND EQUIPMENT.

NOTE: When replacing the AFC1200 System Main Controller Unit, ensure that the new Unit is

configured with the same hardware and software as the Unit being replaced.

8.3.1 Main unit Replacement (Reference Section 3.2.3)

The Main Unit controls overall operations of the AFC1200 Fastening System. The values for
System configuration and operational programs/presets are stored on the components of this
System. Values are stored on a combination of EPROM, EEPROM, battery-backed up
CMOS, and magnetic disk as follows:

UPC PCB:
Hard Disk Drive HDD
Floppy Disk Drive FDD1, FDD2

Backup of preset configuration/
parameter values for fastening
operations

Magnetic disk

FC386 PCB

System configuration

Battery backed up CMOS

MULTI PCB

Preset configuration/parameter
values for fastening operations

EEPROM

FC386 PCB/RDISK daughter
board, MULTI PCB

Operational Program

EPROM

Location

Function

Memory device

To replace the AFC1200 Main Unit as a complete assembly, ensure there is no power to the
System, and disconnect all cables. Proceed as follows:

1. Ensure that the software versions and locations of EPROMs on the FC386 PCB/RDISK

daughter board and on the MULTI PCB are the same in both Main Units. (Refer to 8.3.3
FC386 PCB Replacement and 8.3.2 MULTI PCB Replacement.) Installed EPROMs are
identified by PCB, location, and software version. Example:

RDISK

A3.30

U2

1. Verify configuration of the UPC PCB. Is there a Floppy Disk Drive (FDD) or Hard Disk

Drive (HDD) installed on the UPC PCB? Configure the replacement UPC PCB as
required. Refer to 8.3.6 UPC PCB Replacement.

2. Follow all safety procedures to install the new Main Unit, and perform CMOS setup. Refer

to 8.3.5.

3. When the MULTI PCB is replaced, all the preset configuration/parameter values for

fastening operations stored on EEPROM will be lost. Refer to Chapter 7 for guidance, as
follows: Manual data re-entry from hardcopy backup (7.0.2 Initial Operation) and
reloading preset values from backup magnetic disk media (7.0.3 Backup Operations).

Chapter 8: Maintenance and Inspection

User Console Version A3.53

Page 8-8

REPLACE BATTERY EVERY 3

YEARS (TOSHIBA P/N ER3VCC)

DATE INSTALLED / /