4 - Setting the sensitivity level

The FF310R has three user selectable sensitivity ranges: ‘

Low’, ‘Medium’ and ‘High’.

These ranges allow the technician to choose the degree of sensitivity most suitable to

the particular detection being performed.

4.1 Checking the current sensitivity setting:

The FF310R’s current sensitivity setting is displayed when the “ON/OFF” button is pressed

for 2 or 3 seconds while the unit is ‘ON’ (steady green indicator on). The high sensitivity

setting generates a quick triple flashing of the green LED, a double flashing in the medium

sensitivity range and a single flashing indicates a low sensitivity level setting.

Green LED shows a:

FF300R Tracer set to:

Single (1) flash and beep

Low sensitivity

Double (2) flash and beep

Medium sensitivity

Triple (3) flash and beep

High sensitivity

When turned off, the FF310R will retain the last selected sensitivity setting.

4.2 Procedure to select the FF310R’s range :

1. Unit should be on, if not, turn it on by momentarily pressing the

ON/OFF” button.

2. Press and Hold “

ON/OFF” button for approximately 3 seconds until a beeping and

flashing occurs. This initial beeping and flashing indicates the current sensitivity

level setting. By holding the “

ON/OFF” button pressed, the FF310 will cycle to the

next sensitivity setting following the pattern indicated below:

I-

Low Sensitivity: single (1) flash and beep.

II-

Medium Sensitivity : double (2) flash and beep.

III-

High Sensitivity : Triple (3) flash and beep.

The sensitivity level is selected in the following sequence:

LOW MEDIUM HIGH

Sensitivity Adjustment Sequence

For example: If the FF310R unit is set to

‘MEDIUM’, in order to set the sensitivity to LOW,

press the “

ON/OFF” button until a double beep and flashing occurs (current

setting), keep holding the button pressed and a triple beeping and flashing

occurs (setting now is

HIGH), keep holding the button pressed, until a single

flash and beep indicates that the new setting is

LOW.

5 - How to use the probe:

The probe of the FF310R is built of coiled steel and can be bent as needed, in order to

reach wires in congested or difficult areas. Depending on the circuit characteristics and

the sensitivity setting, the probe will pick-up the signal from the wire in a wide range of

positions . However for the best possible range the FF310R’s probe tip (yellow cap) should

be positioned perpendicular ( at 90°) to the wire being traced and either above or below

it, as shown in Fig. 1 below.

Fig. 1 - Probe positioning

6 - Locating Short Circuits

Refer to the Hook Up Reference Chart in Page 6.
6.1 Observe the limits and safety precautions at all times (refer to the beginning of

this handbook).

6.2 Connect the FF310T (transmitter) in series with the short-circuited wire, making sure

one of the unit’s clips is connected to the circuit’s positive supply (or vice versa for

vehicles with positive supply connected to chassis). A fuse socket connector (in place of

the blown fuse), a connector, etc., provides a convenient hook-up as shown in Fig. 2 and

Fig. 3 in Page 6.

6.3 Switch the transmitter on by pressing the On/Off button and observe if the Red LED

on the FF310T starts flashing. If not check connections, power supply, and in the

case of having connected the unit to any place other than the fuse socket, check

that the circuit’s fuse is installed and in working condition (not open). If necessary

replace with a new fuse with the same ratings.

6.4 Switch the FF310R (tracer) on, and if green LED is turn on.
6.5 Verify that the FF310R is set to the low sensitivity level (single green

LED Flash).

6.6 Slowly sweep the wire, conduit, etc., with tracer, ensuring the tracer’s probe is

perpendicular and above or below the wire being traced and as close as

possible to it .

6.7 Follow the wire or check it at different points, starting from the transmitter and moving

towards the load (accessory, light , etc.) observing the positioning of the probe as

indicated above. Continue this procedure while the audio signal (beeping sound) and

visual signal (flashing Red LED light) indicates the integrity of the circuit. If beeping

and flashing slows down or stops it indicates that the probe is either moving away

from the faulty wire or it has passed beyond the short circuit point.

6.8 If difficult or impossible to get the FF310R Tracer to pick-up any signal, then adjust

the sensitivity to HIGH, and check again if a signal is received.

6.9 Double check positioning the probe before and after the suspected place. If the short

circuit point has been found, the audio/visual indicators will show circuit integrity on

for one position, but not for the other.