13.3 Circuits with multiple loads or branches

When tracing circuits connected to, or which are powering multiple loads and/or

branches (See Fig. 10), and when these circuits are active or live, the bulk of the

current injected into the circuit by the FF310T will be directed to the shorted branch

of the circuit. However smaller amounts of current (or stray currents) will flow to the

other branches as long as these provide a path to ground (i.e. close the circuit).

These stray currents present in the non-shorted branches of the circuit, and

depending on the circuit configuration and physical layout of the wires, could be

picked up by the FF310R (receiver), making the tracing procedures confusing, and

even misleading.

The simplest and most effective way to deal with these cases, is to disconnect or

remove all the loads from the circuit being traced (i.e. removing light bulbs in

example shown in Fig. 10).

14 - Technical specifications

FF310T Transmitter

Voltage range:

6 to 42 Volts DC.

Indicator:

Green LED indicator for Power On or Open Circuits.

Red Led LED indicator for short circuits.

Power source:

9 Volt alkaline battery, Duracell MN1604 or equivalent.

Connector:

Two 5 Amp. universal micro-clips with auto polarity

and 18” long cable.

Battery life:

Approximately 25 hours of use.

FF310R Tracer

Tracer Sensitivity: 3 User selectable levels (Low, Medium and High)

Tracer probe:

Flexible 8” gooseneck insulated steel probe.

Indicator:

Green LED indicator for Power On and Open Circuits.

Red LED indicator for short circuits.

Audio signal for shorts and opens.

Variable flashing and modulated audible signal.

Power source:

9 Volt alkaline battery. Duracell MN1604 or equivalent.

Battery life:

Approximately 25 hours of use.

Fig. 10 - Schematic of a single circuit with multiples loads