1- Hold tester by metal barrel and place free

hand on bare (grounded) metal part of

the vehicle.

2- Place tester point into connector or wire

(pierce insulation if necessary).

3- Tester will light, buzz and vibrate when a

positive voltage is detected.

V-Groove Protector Tip uses:

1- Always insert the V-Groove protector tip on the tester point before carrying or storing

the unit, as this may avoid injuries.

2- Use the V-grove protector tip when piercing wires to prevent the tester point from

side-slipping on the wire and causing injuries or damage.

3- The protector tip may be removed for testing in hard to reach places inside connectors,

sockets, etc.

Replacing the Batteries:

The batteries supplied with the tester will provide years of service under normal use.

When the sound and light starts to fade, remove the screw and pull out the plastic pointer

assembly. Extract the batteries and insert new ones “type Duracell MN9100” or equivalent,

observing the polarity (negative side goes in first). Insert the tester the point assembly,

then align the holes and replace the screw.

16 - CT6100 Fuse Socket Connectors

The CT6100 fuse socket connectors are designed to facilitate in the connection of test

leads of the FF310 to the circuit under test through the fuse box, and can also be used

for all other situations when access to the fuse socket connections are required. These

connectors are supplied in three sizes: Mini, ATO and Maxi.

How to use the CT6100 connectors

1- Choose the connector (Mini, ATO or Maxi) that

matches the fuse socket where the connection

are required.

2- Remove the power to the circuit.
3- Insert fuse connector into the socket

(see figure).

4- Connect test leads to the connectors tabs of the

fuse socket connector.

17 - Care of the Unit

The FaultFinder is a precision instrument and should be treated as such. Damage caused

by mistreatment is not covered by the warranty.

Keep the units in their carrying case when not in use and do not subject to dampness or

severe heat or cold. Do not use the units in the rain, if they should accidentally get wet.

Dry off with a clean paper towel before storing away.

Protect the units from contact with any solvents. Never clean with a solvent or petroleum

based medium such as gasoline, as these chemicals may attack the plastic parts and

cause permanent damage. Never use an abrasive cleaner. Cleaning should be limited

to wiping with a clean damp paper towel with a small amount of soap if required. Dry the

units thoroughly after any cleaning.

The unit is a sealed instrument and contains no user serviceable parts other than the

battery which can be replaced by opening the drawer on the back of the units. Opening

other parts of the units will void the warranty.

16 - Warranty

With the exception of the batteries, your FaultFinder is warranted against defects of

material or workmanship which develop within a period of one (1) year following the

date of purchase by the original owner. Proof of date of purchase will be required when

applying for repair or replacement under guarantee. For this reason, we strongly suggest

that you keep your sales receipt safely in your FaultFinder storage case.

In the event a flaw develops in the FaultFinder, please return it to your dealer who will

arrange repair or replacement. The manufacturer will either repair or replace the tool

(at the manufacturer’s option) free of charge providing the FaultFinder is still under

warranty. If the warranty has expired, there will be a repair charge payable to your dealer

when you pick up the unit. When a unit has been repaired or replaced under warranty, the

replacement unit will continue the warranty period of the original unit for six (6) months

after the date of replacement or until the original warranty expires, whichever is the longest

period. This warranty shall not apply to any defect, failure or damage caused by improper

use or inadequate maintenance or care.

The manufacturer shall not be obligated to provide service under this warranty or to

repair damage resulting from attempts by unauthorized persons to repair or service the

FaultFinder, other than to replace the battery; or to repair damage resulting from improper use.

Specifically if there is evidence of an attempt to open the FaultFinder the

warranty is void.

Any implied warranties arising out of the sale of the FaultFinder including but not limited

to implied warranties of merchantability and fitness for a particular purpose are limited in

duration to the above one (1) year period, the manufacturer shall not be liable for loss of

use of the FaultFinder or other incidental damages, expenses or economic loss. Some

Jurisdictions do not allow limitations on how long implied warranties last or the exclusion or

limitation of incidental or consequential damages, so the above may not apply to you.

Page 13

Advertising