General Technologies CT8025 Automotive Digital Multimeter User Manual

Ct8025, Safety rules, International symbols

Advertising
background image

1. SAFETY RULES

This meter is designed for indoor use at temperatures between 0°C to 40°C and

altitudes up to 2,000m.

To ensure that the meter is used safely, follow all safety and operating instructions in

this operation manual. If the meter is not used as described in this operation manual,

the safety features of this meter might be impaired.

Do not use the meter if the meter or test leads look damaged ,or if you suspect that

the meter is not operating properly.

When using the instrument, keep your fingers behind the finger guards on the plastic

casing and probes.

Disconnect the live test lead before disconnecting the common test lead.

Make sure power is off before cutting, desoldering, or breaking the circuit wires. Small

amounts of current can be dangerous.

Do not apply more than 600 VDC or 600V AC rms between a terminal and ground.

To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC

rms. Such voltages pose a shock hazard.

Never make measurements with the battery cover off.
To avoid electrical shock or damage to the meter, do not exceed the input limits.

2. INTERNATIONAL SYMBOLS

Important information

Dangerous Voltages

see manual

Continuity

AC

Ground

DC

Double Insulation

3. TECHNICAL SPECIFICATIONS

3.1 General Specifications

Display: 3-1/2 digits LCD, max. of 1999 display
Polarity: Automatic, (-) negative polarity indication
Zero adjustment: Automatic
Sample rate: 0.5 Sec.
Over range indication: “1” or “-1” is displayed
Power: 9-volt battery type NEDA 1604, IEC6F22
Battery life: Approx. 50 hours. (w/ alkaline batteries)
Dimension: 5.55”x2.71”x1.41” or 141x 69x36 mm.
Weight: Approx. 6.7 Oz or 190g (with battery).
Accesories: User’s Manual, Test Leads, Protective
Holster, Soft Pouch, K-type temperature
probe and 9V battery

3.2 Electrical Specifications

Accuracies are ±(% of reading + number of least significant
digits) at 23°C ±5°C, less than 75% RH.

4. OPERATION

4.1 Instrument Description

1) Case
2) 3-1/2 Digit LCD display
3) Power OFF position
4) Tachometer function
5) Function/Range Switch
6) Temperature function
7) Resistance function
8) Temperature probe socket
9) Input and common connector
10) DC Voltage function
11) AC Voltage function
12) DC Current function
13) Dwell function

Function

Range

Accuracy

Input

Impedance

Remarks

Overload

Protection

DC Voltage

20V, 600V

0.8%+2

1 M

-

600 Vp-p

AC Voltage

600V

1.5%+5

450 K

40~400Hz

600 Vp-p

DC Current

10A

2.0%+5

-

10 A - 250V

Fuse

Resistance

2000

Ω, 20kΩ

0.8%+3

-

3.2V

max. test

Voltge

250 Vp-p

200kΩ, 2MΩ

1.5%+5

-

20M

3.0%+10

-

Tachometer

500 to 10000

RPM

0.8%+2

Test time: 20 Sec.

250Vp-p

4.2 Measurement Procedures

CAUTION: Maximum Input Voltage is 600Vrms,do not exceed

this rating to avoid personal injuries or damage to
the instrument. The range FUNCTION/RANGE

switch should be set to the range you want to test
before the operation.

CAUTION: Always ensure that the correct terminals are used

for the type of measurement to be made. Avoid
making connections to “live” circuits whenever
possible.When making current measurements en-
sure that the circuit is not “live” before opening it in
order to connect the test leads.

4.2.1 DC Voltage measurement

Connect the black test lead to the “COM” socket and red test lead
to the “V

Ω” socket.

Set the FUNCTION/RANGE switch to the desired range in the
V ” function. If the voltage range is not known beforehand, set
the switch to the highest range and work down as needed.

Connect the test leads across the source or load under
measurement.

The measurement and polarity will be shown the LCD Display
when the probe are connected.

4.2.2 AC Voltage measurement

Connect the black test lead to the “COM” socket and red test lead
to the “V

Ω” socket.

Set the FUNCTION/RANGE switch to the desired range in the
V ” function.

General Technologies Corp.

CT8025

Automotive Digital Multimeter

Function

Range

Accuracy

Input

Impedance

Remarks

Overload

Protection

Temperature

ºF Version

32 to 104ºF

3.0%+1

Built in Sensor

-

-40 to 752

ºF

0.75%+3

K-Type Thermocouple

Probe

752 to 1832

ºF

3.0%+10

Dwell Angle

3 to 8 Cyl.

0-120º

1.5%+2

0.1

º Resoultion

250 Vp-p

Continuity

Buzzer sounds when <100

Test Voltage: 2.4 V Max.

250 Vrms

Diode Test

Test Current:1.0±0.6mA

Test Voltage: 2.4 V Max.

250 Vrms

���

��� ���

�����

���

���

����

���� ����� ���

C

DWELL

����� � ��

TEMP

��

��

��

��

Advertising