1. SAFETY RULES

This meter is designed for indoor use at temperatures between 0°C to 40°C and

altitudes up to 2,000m.

To ensure that the meter is used safely, follow all safety and operating instructions in

this operation manual. If the meter is not used as described in this operation manual,

the safety features of this meter might be impaired.

Do not use the meter if the meter or test leads look damaged ,or if you suspect that

the meter is not operating properly.

When using the instrument, keep your fingers behind the finger guards on the plastic

casing and probes.

Disconnect the live test lead before disconnecting the common test lead.

Make sure power is off before cutting, desoldering, or breaking the circuit wires. Small

amounts of current can be dangerous.

Do not apply more than 600 VDC or 600V AC rms between a terminal and ground.

To avoid electrical shock, use CAUTION when working above 60V DC or 25V AC rms.

Such voltages pose a shock hazard.

Never make measurements with the battery cover off.
To avoid electrical shock or damage to the meter, do not exceed the input limits.

2. INTERNATIONAL SYMBOLS

Important information

Dangerous Voltages

see manual

Continuity

AC

Ground

DC

Double Insulation

3. TECHNICAL SPECIFICATIONS

3.1 General Specifications

Display: 4 digits LCD, max. of 9999 display
Polarity: Automatic, (-) negative polarity indication
Zero adjustment: Automatic
Sample rate: 0.25 Sec., 0.05 Sec. for bar graph
Over range indication: “

OL

” is displayed

Power: 9-volt battery type NEDA 1604, IEC6F22
Battery life: Approx. 70 hours. (w/ alkaline batteries)
Dimension: 5.9”x2.95”x1.34” or 150x75x34 mm.
Weight: Approx. 8.9 Oz. or 252g (with battery).
Accesories:

User’s Manual, Test Leads, Protective
Holster, Hard carriying case, K-type
temperature probe, Inductive pick-up and
9V battery.

3.2 Electrical Specifications

Accuracies are ±(% of reading + number of least significant digits) at 23°C

±5°C, less than 75% RH. For DC/AC current measurement, the maximum cur-

rent of 10 A is for 30 Sec. with 5 min. cool down between measurements.

4. OPERATION

4.1 Instrument Description

1) Case
2) 4 Digit LCD display
3) Secondary Functions Button
4) Auto/Manual Select
5) Function Switch
6) Current Measurment Input
7) Common Input
8) Measurements Input
9) Trigger and Rel. Button
10) Hold and Max/Min. Button

4.2 Display Description

General Technologies Corp.

CT8027

Professional Automotive Digital Multimeter

Function

Range

Accuracy

Input

Impedance

Remarks

Overload

Protection

Resistance

999.9Ω

0.5%+6

-

1.3 V

Max. Test

Voltage

(2.7 V in

999.9Ω

range)

600 Vrms

9.999 kΩ,

99.99 kΩ

0.5%+2

999.9 kΩ,

4.000 MΩ

0.8%+2

40.00 MΩ

1.5%+5

Diode Test

9.999 V

-

< 3.5 V Test Voltage

600 Vrms

Frequency

999.9Hz to

20.0 kHz

0.01%+2

1, 2, 20 and 200 Vrms

Selectable threshold

600 Vrms

Fuel

Injector

0.05 - 250 mS

0.05mS+1

Selectable

+/- Slope,

and

Number of

Cylinders

600 Vrms

0.0 - 100 %

0.04%/krpm +2

0.05 - 250 mS

0.05mS+1

0.0 - 100 %

0.04%/krpm/cyl +2

Tachometer

120-20000 RPM

2 RPM

RPM 4

600 Vrms

60-10000 RPM

RPM 2

30-5000 RPM

RPM 2M

Dwell

0.0º - 360.0º

1.2

º/krpm+1

1 to 12

Cyl.

600 Vrms

0.0º - 100.0º

0.04

º/krpm/cyl +2

Temperature

-20º to 300ºC

3

ºC+1

K-Type Thermocouple

Probe

600 Vrms

301º to 500ºC

2%+1

0º to 572ºF

6

ºF+2

573º to 932ºF

2%+2

Function

Range

Accuracy

Input

Impedance

Remarks

Overload

Protection

DC Voltage

999.9 mV,

9.999 V,

99,99V

0.3%+3

10 MΩ,

16MΩ for

999.9 mV

range

-

600 Vrms

600 V

0.3%+5

AC Voltage

999.9 mV

2.5%+5

10 MΩ,

16MΩ for

999.9 mV

range

50~200Hz

600 Vrms

9.999 mV,

99.99 V

2.5%+5

50~500Hz

DC Current

4000 mA

1.2%+6

0.03V/A

Burden

Voltage

-

10 A - 250V

Fast Acting

Fuse

10.00 A

0.8%+4

AC Current

4000 mA

2.5%+10

0.03V/A

Burden

Voltage

-

10 A - 250V

Fast Acting

Fuse

10.00 A

1.2%+3

1

2

3
4

10
9

5

6

8

7

Analog

Bar Graph

Bar Graph

Overflow

Max./Min.

and Average

Bar Graph/Trigger Polarity

Record

Function

Auto Power Off

Autoranging

Hold

Digital

Readout

Low Battery

Relative
Measure

ment

Advertising