General Technologies LTX12 (-20 to 1200 F) Infrared Thermometer with Laser Sight and ThermoSounder User Manual

Ltx12, Safety rules, International symbols

Advertising
background image

1. SAFETY RULES

This Instrument is designed for indoor use at temperatures

between 32°F to 122°F (0°C to 50°C), altitudes up to 6500 ft.

(2,000 m), and 10% to 90% relative humidity.

To ensure that the instrument is used safely, follow all safety and

operating instructions in this manual. If the instrument is not used

as described in this operation manual, the safety features of this

device might be impaired.

To avoid personal injuries and damage to the instrument use ex-

treme caution when working around hot machine or engine parts,

like radiators, exhaust manifolds, catalytic converters, etc.

2. INTERNATIONAL SYMBOLS

Important information

Refer to the User’s Manual

CAUTION: Laser Radiation

AVOID DIRECT EYE EXPOSURE

1mW Output at 630-670 nm

Class II Laser Product

3. TECHNICAL SPECIFICATIONS

3.1 General Specifications

Display:

3½ digits LCD, Max. of 1999 display

with measuring units, laser on and

backlight indicators.

Resolution:

0.1 to 1 (°C or°F)

Operating Temperature: 32°F to 122°F (0°C to 50°C)
Response time:

<500 ms

(approx.)

Target Size/ Field of View: 10:1 optics ratio with a 1” min. target
Repeatability:

0.5% of reading, plus one digit

Emissivity:

Fixed at 0.95

Laser Pointer:

Laser Diode, < 1mW output

wavelength 630-670 nm, Class II

Power Source:

9-volt battery type NEDA 1604,

IEC6F22 IEC 6LR61

Battery life:

Approx. 20 hours (w/alkaline batteries)

Power Saving:

Automatic shut off after 7 seconds

Wavelength:

7 to 14 µm

Dimensions:

3.13”x 1.88”x 7.0” (80 x 48 x 178 mm)

Weight:

7.6 oz. (215 g) including battery.

Accessories:

User’s manual, soft pouch, and 9 V

alkaline battery

3.2 Measurement Specifications



Accuracies are ±(% of reading + number of least significant

digits) at 23°C ±3°C (73°F ± 6°F) ambient temperature, with less

than 75% relative humidity.

4. OPERATION

4.1 Instrument Description

1) LCD Display
2) Backlight ON/OFF Button
3) °C/°F Select Button
4) ThermoSounder Button
5) LASER ON/OFF Button
6) IR Sensor
7) Laser pointer output
8) Measurement Trigger
9) Battery compartment cover

Function

Range

Accuracy (whichever is greater of)

Resolution

Temperature

ºC

-30°C to 0°C

± 2°C

0.1°C

0°C to 199.9

ºC

1°C or 1.5%+2 (whichever is greater)

200°C to 650°C

2.0% + 2

1°C

Temperature

ºF

-22°F to 32°F

± 4°F

0.1°F

-32°F to 199.9 °F

2°F or 1.5%+4 (whichever is greater)

200°F to 1200°F

2.0% + 2

1°F

General Technologies Corp.

LTX12

Infrared Thermometer with Laser Sight

with ThermoSounder

4.2 Display Description

4.3 Measurement Procedures

4.3.1 Temperature Measurement

Hold the instrument by its handle, point the IR Sensor at the area

or object to measure, and press the Measurement Trigger.

While the Measurement Trigger is kept pressed, the instrument

will continuously measure and update the display with the

temperature of the object pointed at with the IR Sensor.

After the Measurement Trigger is released the instrument will

hold the last temperature reading for 7 seconds, then shut off

automatically.

4.3.2 Field of view or measurement target area

To ensure accurate temperature measurements, make sure

that the target object is larger than the unit spot size, at the

measuring distance.

The smaller the target, the closer you should be.

For maximum accuracy, make sure that the target area is at

least twice as large as the spot size.

!

IR

MEASURE

1

2

3

4

5

6
7

8

9

Continuous measure
Display on hold

°F scale selected

°C scale selected

Measuring mode

Laser on

Backlight on

Low battery warning

Temperature readout

ThermoSounder on

IR

HOLD

MEASURE

D

(D/10)

Spot

Advertising