background image

24

Symptom

Using ON/OFF switch does not work

Machine won’t power up

Cause

•

No power at outlet

•

Make sure power cord is plugged in to

machine and outlet

•

Release e-stop (230v machine only)

•

E-stop nut is loose and stuck down in the

off position (230v machine only)

•

On/off switch needs to be replaced

•

Wiring lead disconnected

Symptom

Tip of drills burn or discolor

Cause

•

Wheel needs to be cleaned

•

Material take off too aggressive

•

Wheel needs to be replaced

•

Grinding wheel obstructed and can’t rotate

•

Grinding motor bad

Symptom

Unable to secure drill in or release drill

from chuck

Cause

•

Tapered shank drill

•

The drill may have a slight taper to the

body

•

Shank of drill larger than body

•

Drill has multiple diameters that are

interfering with jaws

•

Incorrect drill diameter for that particular

chuck

•

Drill flutes are damaged or have burrs

•

Chuck needs to be cleaned

Symptom

Drill incorrectly split

Cause

•

Check settings on the split point fixture

•

Did not align correctly

•

Point Split Tube calibration is off

Symptom

Material take off varies

Cause

•

Wheel not secure to motor hub

•

Wheel calibration is off after new wheel

change

•

Cam dog not properly seated in alignment

slot during alignment set up

•

Drill is pushing back in the chuck during

grinding

•

Operator is not sparking drill out

Symptom

No material take off during grinding

Cause

•

Drill loose in chuck

•

Drill tip not touching the pusher shaft cap

during alignment process

Symptom

Length of time drill is in the grind becomes

excessive

Cause

•

Material take off too excessive

•

Grinding wheel needs to be cleaned

•

Grinding wheel needs to be replaced

Symptom

Lip height concentricity is out of tolerance

Cause

•

Material take off too excessive

•

Chuck needs to be cleaned

•

Sharpening tube needs to be cleaned

•

Chuck is worn out and needs to be

replaced

•

Sharpening tube is worn and needs to be

replaced

•

Wheel is not running true

Trouble Shooting XT-3000 Drill Sharpening

Advertising
This manual is related to the following products: