Pro9F 9000 lbs. Floor Plate Lift

IN50019 Rev. C 03/30/2009

13

STEP 17

:

Remove the vented fill cap from the power unit and fill the reservoir. Use a Ten

Weight (ISO AW32) non-foaming, non-detergent hydraulic fluid (i.e. Texaco HD32 or equal).
The unit will hold approximately twelve quarts of fluid. If a replacement fill cap is required order
from your distributor, a vented cap MUST be used.

STEP 18:

Make the Electrical hookup to the power unit; 220V Single Phase. It is

recommended that a 220 Volt, 30 Amp twist lock plug be installed in the power line just ahead of
the power unit. Use wire capable of supporting a 30-amp circuit.

Warning:

– the wiring must comply with local code. Have a certified electrician make the

electrical hook-up to the power unit. Protect each circuit with time delay fuse or circuit
breaker; 208v-230v single phase 60 Hz 30 amp.


STEP 19:

Do not place any vehicle on the lift at this time. Cycle the lift up and down several

times to insure latches click together and all air is removed from the system. To lower the lift,
both latch releases must be manually released. Latches will automatically reset once the lift
ascends approximately 17” from base. If latches click out of sync, tighten the cable on the one
that clicks first.

STEP 20:

With lift fully lowered, recheck power unit fluid level. Fill as required.


















OWNER / EMPLOYER RESPONSIBILITIES