Input/output setup, continued – Fairbanks AN Series Fairbanks Access Solutions User Manual
Page 80

Section 3: Access Terminal Screens Defined
01/13
80
51299 Rev. 1
Pull Forward Outputs
D
3.3.2. Input/Output Setup, Continued
The pull forward outputs are turned on for the duration of the Pull Forward screen at
the end of the transaction. Typical setup is for Always and any Any Vehicle so the
output will always trigger during the Pull Forward screen. To control the output
conditionally use the conditions described below.
•
Transaction Stage: This refers to the weigh in/out process. The On Start
option refers to weigh in stage, On Complete option refers to the weigh out
stage.
•
MatreX Vehicle Flag: This refers to the type of vehicle in MatreX as to
whether it is marked as an Inbound or Outbound vehicle.
•
Output: Select the output to turn on during the Pull Forward screen. The
duration of the Pull Forward screen is configured on the Timeout and Delay
Setup page.
•
Alternate Outputs: Enable this option to alternate between the two outputs for
each transaction.