Section 3: Programming
08/13
22
51219 -- Rev. 6
3.6 Scale Settings, continued
2.
Division Settings, continued
Display
Descriptions
Set the instrument to 0.1 division size.
Set the instrument to 0.2 division size.
Set the instrument to 0.5 division size.
Set the instrument to 1 division size.
Set the instrument to 2 division size.
Set the instrument to 5 division size.
Set the instrument to 10 division size.
Set the instrument to 20 division size.
Set the instrument to 50 division size.
Set the instrument to 100 division size.
(Only available when
is set to lb.)
3.
– Max. Capacity Settings
Display
Descriptions
Set the maximum capacity of the instrument (from
000001~199999).
a. Press the
key to select the digit and the
key to
increase the value. The first digit on the left can only be set to 0
(zero) or 1 (one). When the value is 0, it does not show on the
LCD display. Press the
key to enter the value.