Load Cell Replacement Steps, Continued

IMPORTANT NOTE:

See

Appendix I

for specific load cell color code and

wiring information.

Load Cell Specifications

DESCRIPTION

SPECIFICATION

Material

Mild Steel

Rated Output

3mV/V

Impedance

350 ohm

Safe Overload

150%

Compensated Temperature Range

-10° C to 40° C

Safe Operating Temperature Range

-10° C to 40° C