Appendix ii: fm control drawings, Groups c, d, e, f & g groups iib & ii a, Hazardous are a – Fairbanks 2800 Series Intrinsically Safe Instrument User Manual

Page 58: Acc-2802, 2800 indic a t or

Advertising
background image

Appendix II: FM Control Drawings

01/12

58

50647 Rev. 9

PCB

ASS

Y

ALONG WITH SECOND 24222,

HAZARDOUS

ARE

A

SU

P

P

L

Y

INTER

F

ACE CABLE

ALSO USE OPTION

A

L

WYE

ADAPTER PN 24257

24223, or 24224 CABLE

FOR SECOND INSTRUMEN

T

24222 or

24224 (50’ MAX)

24223 or

JP2

23649

ACC-2816

PN 24213

120/240

V

AC

P/N 31026 or

SECTION

A

L

CONTROLLER

PCB

ASS

Y

18725

TB2

TB1

TB1

TB2

TB3

TB4

TB5

TB6

PCB

ASS

Y

18720

PCB

ASS

Y

18468

JP1

16

A

WG CABLE

GLAND SEALS

Ca(Co) G

P

D,

F,G 19 uF

Ca(Co) G

P

C,E 5.6

La(Lo) G

P

D,

F,G 7.64 mH

It(Io) = 213 ma

HAZARDOUS

AREAS:

FOR

TB3,

TB4,

TB5 or

TB6:

C

L III

La(Lo) G

P

C,E 2.4 mH

Po = 0.42 w

ENTI

T

Y

OUTPU

T

P

ARAMETERS

C

L II, DIV 1 & 2, G

P

E, F & G

(SEE SHEE

T

5)

GLAND SE

A

L

C

L I, DIV 1 & 2, G

P

C

& D

C

L I Zones 0, 1, 2 G

P

IIB & II

A

GLAND SE

A

L

TO

TRANSDUCERS

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

GROUPS C, D, E, F & G

GROUPS IIB & II

A

SECTION

A

L

CONTROLLER

TB1

TB2

TB3

TB4

TB5

TB6

PCB

ASS

Y

18720

PCB

ASS

Y

18468

JP1

PCB

ASS

Y

18468

TB5

TB1

JP1

TB6

CONTROLLER

PCB

ASS

Y

18720

TB3

SECTION

A

L

TB2

TB4

JP1

TB5

TB1

PCB

ASS

Y

18468

TB4

TB2

TB3

TB6

SECTION

A

L

PCB

ASS

Y

18720

CONTROLLER

TO

TRANSDUCERS

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

TO

TRANSDUCERS

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

TO

TRANSDUCERS

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

GLAND SE

A

L

GLAND SEALS

GLAND SEALS

GLAND SEALS

U

P T

O 4

ACC-2802s

PLUG SE

A

L FOR

TB2 ON LAS

T

ACC-2802

16

A

WG CABLE

16

A

WG CABLE

16

A

WG CABLE

50 FEE

T

MAXIMUM

HAZARDOUS

ARE

A

Vt(

V

o) = 7.875v

uF

A

P

P

REV DESCRIPTION D

A

TE

REVISIONS

GS6

GS5

ACC-2802

ACC-2802

ACC-2802

ACC-2802

31 FEE

T

MAXIMUM

31 FEE

T

MAXIMUM

31 FEE

T

MAXIMUM

2800

INDIC

A

T

OR

(PN 21234)

ADDED

THIS SH PER ECO 13469

4

07-02-03

MJQ

ADDED SHEETS

11 & 12 PER ECO 14036

6

G

A

L

6-9-09

G

A

L

2-2-

11

ADDED 31026 CABLE PER ECO 14187

7

T

itle

Size

Document Number

Date:

Sheet

2

2

1

1

B

B

A

A

21943

CONTROL/INS

TA

LL

A

TION DR

A

WING FOR 2800 INDIC

A

T

OR

FAIRBANKS SCALES

2176 PO

R

TLAND S

T.

B

9

T

uesda

y, July 03, 2001

SUITE 1

S

T,JOHNSBU

RY

V

T. 05819

NO CHANGE M

A

Y

BE MADE

T

O

THIS DR

A

WING OR RE

LA

TED

COMPONENTS WITHOU

T

PRIOR WRITTEN

APPRO

V

A

L OF

FAC

T

O

RY

MUTUAL!!!!

Advertising