A. format: fairbanks computer (fbputr), continued, B. 4. format : consolidated controls (concon) – Fairbanks 2800 Series Intrinsically Safe Instrument User Manual
Page 66

Appendix IV: Continuous Output Data Streams
01/12
66
50647 Rev. 9
A. FORMAT: FAIRBANKS COMPUTER (FBPUTR), CONTINUED
Character
1 2 3 4 5 6 7 8 9 10
Data String
STX 4 y x x x x x x ETX
x
= weight
y
= Second digit of a id code i.e. 4y where y= 0, 1, 3, or 4.
40
= Gross lb, oz, lb-oz, ton, or gallons
41
= Net lb, oz, lb-oz, or ton
43
= Gross kg or grams
44
= Net kg, grams, or gallons
Underload condition data stops transmitting.
Overload condition data is transmitted as the id followed by dashes.
Leading zeros are suppressed.
B. 4. FORMAT : CONSOLIDATED CONTROLS (CONCON)
Character
1 2 3 4 5 6 7 8 9 10
Data String
STX x x x x x x U E CR
x
= Displayed weight; Gross or Net
U
= Units selected
L
= pounds
K
= kilograms
O
= ounces
G = grams
T
= tons or gallons
E
= Error flag
M
= motion
O
= underload or overload
Space
= no errors
Leading zeros are suppressed.