General Tools and Instruments CMR35 User Manual
Page 31

Resistance Measurement
Range
Resolution
Accuracy
Remarks
Maximum
input voltage
400Ω
0.1Ω
4kΩ
0.001kΩ
40kΩ
0.01kΩ
400kΩ
0.1kΩ
4MΩ
0.001MΩ
±(3% of reading
+ 5 digits)
40MΩ
0.01MΩ
±(5% of reading
+ 5 digits)
Continuity Check
Range
Resolution
Accuracy
Maximum
input voltage
400Ω
0.1Ω
Alarm sounds for resistance
<~100Ω
600V
Diode Test
Range
Resolution
Accuracy
Remarks
Maximum
input voltage
1.000V
0.001V
±(10% of reading --Open circuit
600V
+ 5 digits)
voltage is ~1.5V
Frequency Measurement
Range
Resolution
Accuracy
Remarks
Maximum
input Voltage
5Hz
0.001Hz
50Hz
0.01Hz
500Hz
0.1Hz
5kHz
0.001kHz
50kHz
0.01kHz
100kHz
0.1kHz
*For measurements below 64°F (18°C) or above 82°F (28°C), decrease stated accuracy
by an additional 10% per 1°C change
31
±(1% of reading
+ 5 digits)
--Open circuit
voltage is ~0.4V
--Measuring current
varies with
resistance
measured
±(0.7% of reading
+ 5 digits)
--Accuracy stated
for sine wave
600V
600V