Display Legend

: indicates reading is higher than high alarm setpoint

for that parameter

▼: indicates reading is lower than low alarm setpoint

for that parameter

%RH: relative humidity unit

°C: Celsius temperature unit

°F: Fahrenheit temperature unit

[-]188.8: Humidity or temperture value or one of the

following four working status indications

LOG: Unit is logging data

- - -: Unit is in standby mode, ready to log data

FUL: Internal memory is full (and logging has been

stopped)

CON: Unit needs to be configured by software

SETUP INSTRUCTIONS

INSTALLING/REPLACING THE BATTERY

The HT20 uses a 3.6VDC “1/2 AA” Lithium-ion battery.
To open the battery compartment, use a paper clip or a
screwdriver with a fine point to push in the silver flange
showing through the small square hole in the rear of the unit

7

Fig. 1b.
All possible
display
indications
on the HT20

LATCH

HT20 - Manual–FINAL_REV_0316121_awb 3/16/12 4:02 PM Page 7