2. Ground the tester by touching your

thumb to the metal button at the end
of the screwdriver’s handle.

Ꮨ

Warning

Ꮨ

DO NOT TOUCH the exposed metal
portion of the screwdriver tip while it is
contact with the live side of an outlet or
a current-carrying conductor.
3. If voltage is detected, the neon bulb

inside the clear portion of the handle
will glow. If you are testing outdoors
or in a brightly lit area, shield the
handle with your hand to provide a
better view of the bulb.

SPECIFICATIONS

Voltage Detection Range:

80 to 250VAC/DC

Operating Temperature:

41° to 104°F (5° to 40°C)
@ <80%RH

Dimensions:

5.63 in. (143mm) long x 0.5 in.
(13mm) maximum diameter

Weight: 1 oz. (28g)

4

DANGER

Electric

Shock Risk