9060 Cascade Low Voltage Controller - Introduction

CP-13-02.2

10

OPERATOR INTERFACE

The 9060 Controller shown in Figure 3, has a
simple operator interface consisting of 7 LEDs
(Light Emitting Diodes), one (1) power switch,
seven (7) buttons, one (1) current LED bar-
graph, and two (2) screens containing seven-
segment displays.

SWITCHES

Power Switch

The 9060 Controller contains a single rocker
switch for power On/Off selection. When the
unit is powered on, the screens should be lit
and display the gun type information and the
software version number for a short period of
time.

LEDs

High Voltage On Indicator

The red High Voltage On Indicator is lit when a
trigger signal has been received by the unit and
the high voltage output from the cascade has
been enabled.

Fault Indicator

The red Fault Indicator is lit when a fault occurs
as determined by the microprocessor. When a
fault occurs the light will turn on and the identifi-
cation code (ID Code) for the fault will be
displayed, blinking, on the µA meter display.
For more information on the faults and fault ID
codes, please refer the Fault Descriptions
section in the Operations portion of this manual.

Figure 3: 9060 Operator Interface

LOCAL Mode LED Indicator

The LOCAL mode LED indicator is a left
pointing triangle and is located on the left side
the HV control button on the center of the
operator interface. This LED is lit when the
Controller is in LOCAL mode.

REMOTE Mode LED Indicator

The REMOTE mode LED indicator is a right
pointing triangle and is located on the right side
the HV control button on the center of the
operator interface. This LED is lit when the
Controller is in REMOTE mode.

Active Preset LED Indicators (3)

The active preset LED indicators are located
directly above each of the Preset Buttons.
When a preset button is pushed to select the
desired preset, in READY or RUN mode, the
preset LED indicator directly above the button
pressed will light up. Only one (1) preset light
should be lit at any one time.

The preset LED indicators also have alternate
meanings for the remote input/output (I/O)
monitoring diagnostic mode. When in this
mode, the preset LED indicators specify which
diagnostic sub-mode is currently activated. For
more information, please refer the remote input/
output (I/O) monitoring diagnostic mode portion
of the operations section of this service manual.

BUTTONS

The seven buttons on the operator interface are
used to select the KV presets, reset overloads
and faults, access other modes and to navigate
as well as modify information that is displayed
on the two seven-segment display screens (µA
and kV).

The following lists the standard operating mode
behavior for each button, for behaviors for other
modes, please refer to the operation portion of
this service manual for the specific mode.

Preset 1 Button

The Preset 1 Button (on the left below the kV
display) is used by itself to select “Voltage
Preset 1” in the normal operating mode. If