9060 Cascade Low Voltage Controller - Operation

CP-13-02.2

36

Be careful when using the parameter

adjustment mode, if you select something
and are unsure if you’ve changed it, dese-
lect it using Preset 2.

!

C A U T I O N

Modifying a Parameter

After a parameter has been selected using
the preset 2 button and is flashing, the + and
- keys can be used to increase or decrease
the value of the parameter. Each parameter
has its own incremental values and limits
listed in the Adjustable Parameters Table.
When the parameter value has been adjust-
ed appropriately, it must be saved using the
save parameter button (preset 1). If the
select (preset 2) button is pressed during
modification, all changes will be lost and the
parameter will be deselected.


Loading Parameter Defaults

For any parameter setting, there is a default
value. For example, there is a default overload
value for each gun type. After a parameter has
been selected, the default value can be loaded
by pressing the preset 3 button. This new,
default, value will only be saved if the parame-
ter modifications are saved using the Save
parameter button.

Saving Parameter Modifications

After a parameter has been selected, any
changes to the value can be saved by pressing
the preset 1 button. This will save the changes
to memory and de-select the parameter.

The saved changes to parameters will

immediately take effect and do not require
power cycling of the unit.

N O T E

Exiting the Parameter Adjust-
ment Mode

When no parameter is selected, pressing the
Reset key will exit parameter adjustment mode.

Figure 30: Summary of Adjustment Operations

LOCAL MODE ONLY
OPERATIONS

Voltage Setpoints

The voltage on the 9060 Cascade Low Voltage
Controller is adjustable between 20 kV and full
kV DC. In the LOCAL mode, there are 3
voltage setpoints (presets); 1, 2, and 3. Each of
these setpoints can be individually adjusted
between 20 kV and full kV DC. The three (3)
factory preset voltages are listed in the follow-
ing table:

The full kV DC value is determined by

the gun type configuration for the particu-
lar applicator that is being used, NOT the
full KV value of the cascade.

N O T E

Factory Presets

Preset

Value

1

Full kV minus 20 kV

2

Full kV minus 10 kV

3

Full kV

Setting the Setpoint

When the applicator is off in LOCAL mode, the
present setpoint can be changed by pressing
the 1, 2, or 3 buttons on the front panel shown
in Figure 31. The setpoint that is currently
selected will have the LED light in the upper
right corner of the button lit.