9060 Cascade Low Voltage Controller - Maintenance

43

CP-13-02.2

General Problem Possible Cause

Solution

Blank Display

1. No power

2. Blown fuse

3. Faulty +24 volt power supply

1. Check the power connections and verify

they are fully connected and power is avail-
able. Power cycle the unit off and back on.

2. Check Fuses and replace if blown using

the replacement fuses inside the lid of the
unit.

3. Check green led on 24 volt power supply

when power is applied LED must be on. If
the LED is not on, replace 24 volt power
supply.

MAINTENANCE


TROUBLESHOOTING GUIDE

FAULT TROUBLESHOOTING GUIDE

Before troubleshooting gun and control unit problems, flush the gun with solvent and purge

with air. Some of the tests will require high voltage to be applied to the gun, so the gun must
be empty of paint and solvent.

!

W A R N I N G

Fault

Description

Solution

Cable Fault (CF)

The Cable Fault indicates the con-
trol unit does not detect a high
voltage section on the end of the
cable. The fault typically occurs at
a high voltage trigger.

1. Check for loose wiring between the pc

board connector and the high voltage sec-
tion by pulling on each wire. Repair if nec-
essary. Insure both connectors are secure
and re-test for CF fault.

2. Replace high voltage section or send unit

in for repair.

3. Send unit in for repair.