Turbine Speed:

10,000-60,000 rpm max.

Turbine Type:

Impulse - Front Exhaust

Weight:

(See outline drawings)

Length & Diameter:

(See outline drawings)

Turbine Air Consumption:

(See "Turbine Speed Charts"

in this section.)

Bearing Air:

80 psi nominal (551 kPa)

60 psi min., 100 psi max.

(413-689 kPa)

2-3 SCFM (57-85 SLPM)

Target Distance:

6-12 inches (152-305mm)

Recommended

Brake Air:

100 psi (689 kPa)

Fluid Pressure:

150 psi max.

SPECIFICATIONS

Mechanical

Fluid Flow Rate:

500 cc's/max.

(paint or solvent)

Rotator Atomizer

Change Time:

(Quick Change Time)

Approx. 20 sec.

Bell Change Time:

Approx. 40 sec.

Bell Cleaning Time:

Approx. 2-3 sec.

Speed Readout Pickup:

Magnetic

(2 pulses/rev.)

Power Supply:

MicroPak-RansPak

1000 Cascade

Voltage Master II

100kV

Special Control:

Serial Atomizer

PulseTrack 2

* Paint Resistance: 1 MΩ to ∞ (Solventborne Direct

Charge Applications)

* Ransburg Meter (See "Accessories" in the "Parts

Idenetification" section for part numbers.)