TROUBLESHOOTING GUIDE (Cont.)

General Problem Possible Causes

Corrective Action

No Turbine Air

Speed Feedback

Fault

No Fluid Flow

1. Turbine drive air not

present

2. Bearing air return signal

not present

3. Brake air is activated

1. Damaged fiber optic cable

between robot plate and

control panel

2. Connection at mounting

manifold is loose

3. Fiber optic transmitter failure

4. Bad transceiver module

5. Excessive vibration

6. Fiber optic cable not fully

installed

1. Turbine is not rotating

2. System fluid regulator

does not actuate

3. Fluid valve does not

actuate

1. Verify supply air pressure.

2. a. Verify bearing air return signal.

b. Increase bearing air supply pressure to 90

psig (±10 psig) (620.5 +/- 68.9 kPa) mini-

mum 60 psig (413.7 kPa).

3. Remove brake air signal (turbine air and

brake air must be interlocked to prevent

both from being used simultaneously).

1. Repair or replace fiber optic cable.

2. Reinstall cable.

3. Replace fiber optic transmitter.

4. Replace transceiver module.

5. a. Check bell cup for damage.

b.

Check bell cup for excessive paint build-up.

c. Ensure bell cup is tightenend properly.

d.

Check cup and shaft tapers for cleanliness.

6. Insert cable to full depth.

1. Verify rotation of turbine (the paint valve air

pilot must be interlocked with the turbine

speed feedback signal to ensure that paint

does not flow into the air bearing).

2. a. Verify fluid supply.

b. Verify that iar pilot signal is present.

3. a. Verify that air pilot signal is present.

b. Fluid valve air pilot pressure is too low. In-

crease air pressure to 70 psig minimum

(482.6 kPa).