6. Any other interlocks required by local code,

national code, or international code.

7. High voltage must be interlocked with the

booth entry door.

HIGH VOLTAGE CABLE

ASSEMBLIES

General Instructions

1. When routing cable, ensure that no chaffing,

binding, or pulling on the cable will occur. Maintain

at least a 4-inch bend radius. When possible,

sleeve cable with the appropriate sized tubing for

external cable protection. Torsion stress should

be minimized.

2. Considerations should be taken when routing

cables next to other cabling and fluid tubing. Be

cognizant of the placement of such cable near

control wires and fluid lines. Follow NEC wiring

standards where applicable. Separation of AC,

control wiring, and fluid tubing is advisable.

3. To ensure that all cable connections are clean

and free of foreign materials, wipe with Naphta.

This also applies to the cascade, splitter, and

applicator connectors.

4. Apply dielectric grease (LSCH0009-08) on

all cable end connectors (cascade, splitter, and

applicator) to displace any encapsulated air.

5. Each time a cable is replaced, the nut assembly

(78441-00) must also be replaced.

6. Ensure that no conductive sponges are used

in any connector!

7. A10560-XX cables are not to be modified in

the field. To do so will void any and all warranties

that may exist.

HIGH VOLTAGE CABLE

CONFIGURATIONS

There are two (2) high voltage cable assemblies

available:

A10560-XX is a shielded cable and is the most

flexible. It is available in several lengths per the

"Accessories" chart in the "Parts Identification"

section.

79006-XX is a metallic core conductor cable with

a polyethylene jacket and an exterior sleeve. It

comes pre-assembled with banana jacks at each

end.

A third option is to build your own cable to a specific

length not to exceed 100-ft. (30.5 meters) in length.

A non-shielded metallic conductor cable (SSW-

1064) is used. the end user must intall the EPS-

4245 banana jacks. It is hightly recommended

that an insulating jacket (79007-00) be installed

over the assembly to protect it from damage.

HIGH VOLTAGE

INSTALLATION

CONFIGURATIONS

Cascade RP1000 Installation

(74793-XX) with MicroPak Control

1. Loosen connector nut assembly from the

cascade.

Apply dielectric grease (LSCH0009-08) on the

cascade end of the high voltage cable and in the

cascade tube.

Insert the cable through the back of the

compression nut followed by the plastic gripper

and sleeve

(78441-00).

Insert the high voltage cable through the cascade

high voltage tube, all the way through the nut

assembly to the banana plug socket in the cascade

tube assembly.

Aerobell - Installation

32

LN-9264-08.2

Ransburg