Ransburg, Aerobell - installation – Ransburg Aerobell (Std.) Rotary Atomizer A12381 User Manual

Page 37

Advertising
background image

2. Loosen one of the connector nuts from the high

voltage splitter assembly.

Apply dielectric grease (LSCH0009-08) on the

cascade end of the high voltage cable and in the

splitter assembly.

Slide the fitting and start threading on to the high

voltage cascade tube threads. (Each piece of

the fitting may have to be slid into place starting

with the sleeve followed by the plastic gripper and

then the nut.)

Turn the nut hand tight.

Wrench tighten the nut 1/2 turn.

Pull on cable to ensure a secure fitting. If the

cable is loose and can be pulled free, then reinsert

cable into cascade and follow these steps again

with an additional 1/2 turn on the nut.

2. Attach the ring lug of the green ground wire

(shield cables A10560-XX only) securely to a

known good earth ground source.

High Voltage Splitter Installation

(78152-00) (See Figure 8)

The splitter can be used for up to four atomizers.

1. Remove nut from end of cascade extension

tube (78441-00). Apply a small amount of dielectric

grease to tip of the banana jack of the high voltage

splitter assembly. Slide the banana jack into the

cascade tube until it bottoms. Tighten onto threads

by turning clockwise until snug.

78152-00

HV SPLITTER

74593

CASCADE

PLUG FOR UNUSED PORT

(3) SUPPLIED

HIGH VOLTAGE WIRE FROM APPLICATOR

(NON-REPAIRABLE)

Insert the high voltag e cable through the back of

the nut all the way through the nut assembly to

the banana plug socket in the splitter body.

Turn the nut hand tight.

Wrench tighten the nut 1/2 turn.

Pull on cable to ensure a secure fitting. If the

cable is loose and can be pulled free, then reinsert

cable into high voltage splitter and follow these

steps again with an additional 1/2 turn on the nut.

3. Attach the ring-lug of green ground wire

(shielded cables A10560-XX only) securely to a

known good earth ground source.

Voltage Master 2 (78789) Cable

Installation

The Voltage Master 2 contains a control panel

and a power supply (LEPS5001). To install the

high voltage cable, loosen the nut on the top of

the LEPS5001-02 power supply tank and insert

the high voltage cable through the nut and rubber

gromment and push into tank until the banana jack

is fully seated. Tighten the nut firmly by hand to

grip the cable.

To connect multiple applicators, you can connect a

high voltage cable from LEPS5001-02 tank to the

input of a LEPS5000-05 junction tank. Up to five

(5) applicators can be supplied from the junction

tank. High voltage cable connection on this tank

is the same as the Voltage Master 2 tank.

Another method for connecting multiple applicators

from the Voltage Master 2 is to "daisy chain" by

using high voltage fittings A10030-00 and A10030-

02 (see "Figure 3 - Typical Multiple Applicator

Configuration Voltage Master 2 and PulseTrack

2 Speed Control" in the "Introduction" section).

Aerobell - Installation

33

LN-9264-08.2

Ransburg

Advertising