Parameter adjustment mode, 9060 cascade low voltage controller - operation, Gun type/firmware version mode – Ransburg 9060 LV Cascade Controller 80120-XXX User Manual

Page 40: Navigating parameters, Selecting/deselect parameters, Adjustable parameters

Advertising
background image

9060 Cascade Low Voltage Controller - Operation

35

CP-13-02.3

Figure 29: Parameter Adjustment Mode (Overload)

To navigate through the digital indexes, use the
- and + buttons. Both buttons change the index
by 1 for each press and will automatically wrap
back around when the either end of the list is
reached.


Gun Type/Firmware Version
Mode

This sub mode will display the gun type display
value on the kV display and the firmware
version number on the µA display as shown
during startup in Figure 18 during startup. As
this is a sub mode of the remote I/O monitoring
diagnostic mode, it will not have a limited
display duration and will remain on the screen
until either a different sub mode is entered or
the diagnostic mode is exited.






PARAMETER
ADJUSTMENT MODE


Certain parameters within the 9060 Cascade
Low Voltage Controller can be adjusted de-
pending on the applicator being used. To enter
the parameter adjustment mode, press the
preset 1 and preset 3 keys at the same time.
This will bring up the parameter adjustment
mode as shown in Figure 29. A summary of
key operations for parameter adjustment mode
is shown in Figure 30.

In parameter adjustment mode, the kV display
will show the 2-character code for the parame-
ter and the µA display will show the currently
set value for the parameter. Each parameter
has its own specific range limits, increment
values, and indicators (if applicable). The
adjustable parameter table lists the currently
available parameters by character code along
with their attributes.

Navigating Parameters

When a parameter is currently not selected, the
- and + buttons are used to navigate from one
parameters to another. If the - button is
pressed the previous parameter will be display.
If the + button is pressed the next parameter
will be displayed. The parameter adjustment
menu has a wrap around indexing, so it if the
end of the parameter list is reached in one
direction it will automatically moved to the other
end.

Selecting/Deselect Parameters

The preset 2 button is used to select/deselect
the currently displayed parameter to allow it to
be modified. When pressed to select the
parameter, the value on the µA display will
begin flashing. This indicates the parameter
has been selected and can be edited. If the
preset 2 button is pressed when a parameter is
already selected, it will be deselected and all
modifications will be lost. The parameter’s
value will stop flashing indicating it has been
deselected.

The Parameter Adjustment Mode is ON-

LY

available for the ES (Esta-Quick, Evolv-

er SE) and Ab (Aerobell 168) automatic
applicators.

N O T E

Code Parameter Min/Max Inc.

Indicators

OL

Current

Overload

20/190

5

Decimal marker

on code means

overload jumper is

installed

Hd

Startup

Holdtime

2/15

seconds

0.5

sec.

N/A

Adjustable Parameters

SA

Sample

Time

2-50

1

Available only

on 51X Units

SE

Sensitivity

1.0-12.0

1

Available only

on 51X Units