TROUBLESHOOTING GUIDE

General Problem

Possible Cause

Solution

DELIVERY

1. No main supply air
2. No color selected
3. Wrong color selected
4. No paint connected to CCV
5. Paint not pressurized
1. No main supply air
2. No color selected
3. Wrong color selected
4. Loose connection
5. Defective air switch

Fluid

LEAKAGE

DEFICIENT DELIVERY

Air (To CCV)

1. Turn supply air on or reconnect to box
2. Select a color
3. Select proper color
4. Reconnect paint or select proper color
5. Check users supply
1. Turn supply air on or reconnect to box
2. Select a color
3. Select proper color
4. Tighten connection
5. Replace defective switch

1. Hole in tubing
2. Loose connection
1. Loose connection
2. Hole in air tubing
3. Bad switch
1. Loose connection
2. Worn fluid tubing

Air

Air (Insided

Color Select Box)

1. Replace worn tubing
2. Tighten connection
1. Tighten connections
2. Replace air tubing
3. Replace defective switch
1. Tighten connections
2. Replace worn fluid tubing

Fluid

1. Insufficient supply air
1. Low supply pressure
2. Clogged or obstructed fluid lines
3. Clogged or obstructed CCV stack

Air
Fluid

1. Check air regulator
1. Increase supply pressure
2. Clean or replace
3. Clean as required