INTRODUCTION

DESCRIPTION

Color Select System

The CCV-6100 Color Select System is a manu-

ally controlled pneumatic color change system.

The system consists of one or two color change

boxes, a Color Change Valve Stack, and 1/4 inch

OD poly tubing. The system allows for up to and

including (15) different colors. Color changes are

made using CCV-403-SS color change valves.

Valve

The CCV-403-SS is a pneumatically operated fluid

valve designed for use in paint spray application

systems. The valve can be used in a variety of

other applications. The valve can be used sepa-

rately for on/off control of paint to a spray atom-

izer; or, as part of a multi-color manifold assembly

where colors can be quickly flushed and changed

when a color change is desired.

All parts that come in contact with the fluid mate-

rial are made of either stainless steel or PTFE

that is impervious to most solvents. All other

parts of the valve are made of brass, stainless

steel, nickel-plated brass or hard coated (anod-

ized) aluminum. The valve is constructed with a

smooth, unobstructed fluid path that allows for

faster flush cleaning, and also less pressure re-

striction. The valve body has two fluid inlet ports

that allow fluid to circulate through the valve on

a continuous basis. A plug is provided when this

feature is not to be used. The double inlet ports

also allow two valves to be used as a fluid on/off

control and dump system.

Main Box

The main box consists of two six-position pneu-

matic switches. The top switch switches between

off, air solvent and color. The color select posi-

tion activates the bottom color switch and the

secondary box (if more than five colors are to be

used). The bottom switch is used to select colors

1 through 5. All internal plumbing is 5/32 nylon

tubing. The external bulkhead fittings are for 1/4

inch O.D. tubing, including the supply air fitting.

When High Voltage is on, both Solvent Flush

and Air Push are locked out so they cannot be

triggered.

Secondary Box

The secondary box also consists of two six posi-

tion pneumatic switches. The top switch selects

color 6 through 10, the bottom 11 through 15. All

internal and external tubing connections are the

same sizes as the main box.

>

When using the secondary box, all color

select switches not in use must be set in

the OFF position.