Operating instructions – Robinair 34788-I Recovery, Recycling, Recharging Unit User Manual

Page 14

Advertising
background image

12

Operating Instructions

Recharge the A/C System

1. Press CHARGE. Press CHARGE again to toggle

between a high-side charge, a low-side charge, or
both.

Note:
• Charge mode after injecting oil will allow only a high-

side charge.

• The blue light on the control panel indicates a low-

side charge; the red light indicates a high-side charge.
See Figure 8.

2. Accept the default weight by pressing START / YES,

or type in a weight using the number keys, and
press START / YES.

3. Select START / YES to perform an oil inject; select

STOP / NO to skip the oil inject.

4. After a valid charge weight is entered, the display reads

CHARGE IN PROGRESS / DO NOT DISTURB

X.XX LBS. (X.XX KG)

Moving or bumping the unit at this point may result

in an incorrect reading.

Note:
• During a charge cycle, if the unit fails to transfer

refrigerant due to low tank pressure, the charge
process is automatically interrupted and the unit
operates in a mode to build tank pressure. Once
tank pressure is sufficient, the unit automatically
completes the charge.

• When the charge cycle gets close to the weight

entered in Step 2, the unit slows down. It’ll charge,
settle, charge again, settle, etc., with the blue/red
lights illuminating accordingly.

5. When the charge is complete, the display reads

CHARGED XXX LBS (KG)

PRESS START TO EQUALIZE HOSES

STOP TO EXIT

Press START / YES to equalize pressure in the

service hoses. This ensures all liquid refrigerant
trapped in the hoses is transferred to the vehicle A/C
system for an accurate charge.

Note: Answering STOP / NO to this message will

cause the machine to display

COMPENSATING HOSES

DO NOT DISTURB

Operating Tips

After selecting the CHARGE function and
entering a desired weight, if the weight
entered will leave less than 2 lbs. (.91
kg) of refrigerant in the internal tank after
charge, the charge function will not start.
The display reads

INSUFFICIENT REFRIG.

PRESS ANY KEY TO EXIT

Refer to the Maintenance section of this
manual for instructions to Manually Refill
the Internal Storage Vessel (ISV).

Red Light indicates

High-Side Charge

Blue Light indicates

Low-Side Charge

Figure 8

Advertising
This manual is related to the following products: