20

Replacement

Component

Part No.

Filter -Drier

34724

Calibration Weight

540066

Service Coupler Set
(high- and low-side couplers)

18192

Service Hose Set
(high- and low-side hoses)

34722

Vacuum Pump Oil
(case of 12 quarts)

13203

Replacement Parts

Maintenance

Vacuum Pump Oil
(case of 4 gallons)

13204

Maintenance Kit

13172

Vinyl Dust Cover (optional)

17492

Vehicle Database (optional)

34411

High-side Storage Port

546882

Low-side Storage Port

546883

Tank Fill Hose Filter

10233

Replacement

Component

Part No.

Inspect the unit periodically for leaks.
The manufacturer does not reimburse for
lost refrigerant.

Check for Leaks

Check the unit for leaks every three months, or as
specified by law in your jurisdiction.
1. Turn off , and disconnect the power cord from the

outlet.

2. Open the rear door; remove top cover and front

panel.

3. Use a leak detector to probe all connections for

refrigerant leaks. Tighten fittings if a leak is indicated.

4. Reassemble the body panels, and close the rear

door.

Adjust Tank Fill Level

When connected to a refrigerant source, the unit
maintains a default value of 15 lbs. of refrigerant in the
internal storage vessel. This value may be adjusted up
or down to suit the application.
1. Press MENU.
2. Use the arrow keys to scroll through the menu to

ADJUST TANK FILL LVL, and press START / YES.
The unit displays

LEVEL: 15.00 LBS.

ENTER TANK FILL LVL

LIMIT: 4 TO 17 LBS.

PRESS START / YES TO SAVE

3. Use the keypad to enter a value between 4 lbs. and

17 lbs., and press START / YES.