Maintenance

General Maintenance

1. On a regular basis, wipe off the unit using a clean

cloth to remove grease and dirt.

2. Periodically check internal components for leaks; over

time, fittings can loosen as the unit is moved. Open
the door panel, and trace lines using a leak detector.
Check connections on the back of the unit. Tighten
any loose fittings or connections you may find.

Electrical Protection

The unit is equipped with a 15 amp circuit breaker on
the back panel. See Figure 10. If the breaker trips, its
button will pop out. A tripped circuit breaker will cause
the unit to lose all power.
Press the circuit breaker button to reset.

Manually Fill the
Internal Storage Vessel (ISV)

This menu item is used to transfer refrigerant from a
source tank to the internal storage vessel.
Note: If a refrigerant source tank remains connected to
the unit during normal operation, the correct amount of
refrigerant will automatically be maintained in the ISV.
The ISV may be manually refilled, if necessary.
1. Press Menu, and use arrow keys to select MANUAL

REFILL. Press START / YES. The unit displays

CONNECT SOURCE TANK

START TO BEGIN

2. Connect the fill hose to a full source tank, and open

the source tank valve.

3. Install the source tank, and secure it to the unit

with the source tank strap in such a way that liquid
refrigerant is supplied to the connection.

4. Press START / YES to begin. The display shows

TANK FILL IN PROGRESS

TRANSFER XX LBS

5. The unit automatically stops when the preset tank fill

level is reached, or press STOP / NO to exit.

Figure 11

Side View

Fill Hose

Power

Cord

Source

Tank

Strap

Low- and

High-Side

Hoses