6

Set Tank Fill Level

The operator may either accept the unit’s pre-set
default weight of 15 lbs. (6.8 kg) of refrigerant stored in
the internal storage vessel (ISV), or change the amount
to accommodate the application.
The unit displays

LEVEL: 15.00 LBS.

ENTER TANK FILL LVL

LIMIT: 4 TO 17 LBS.

PRESS START / YES TO SAVE

1. Press START / YES to accept the default amount, or

use the keypad to enter a desired amount and press
START / YES.

Add Oil to the Vacuum Pump

CAUTION: The vacuum pump is shipped without
oil in the reservoir. Failure to add oil to the vacuum
pump will damage the pump.

The unit displays

ADD 5 OZ OF NEW OIL

TO VACUUM PUMP

START TO CONTINUE

1. Remove the brass plug from the vacuum pump oil fill

port. See Figure 3.

2. Attach the flexible tube/cap to the oil bottle; pour only

five (5) ounces of vacuum pump oil into the fill port.
Note: You will top off the oil in the next step as the
vacuum pump is running.

3. Press and release the START / YES key. While the

vacuum pump is running, slowly add oil until the
level rises to the center of the reservoir’s sight glass.

4. Press the STOP / NO key to stop the vacuum pump,

and install the brass plug in the fill port.

5. Press START / YES to continue.

Setup

Figure 3

Sight

Glass

Fill Port

Vacuum Pump

Sight Glass

CAUTION: The unit is programmed

to run the setup procedure as outlined
here. To prevent personal injury, do
NOT operate the unit at any other time
without the brass plug installed, because
the vacuum pump is pressurized during
normal operation.