Set u introduction, Pressure gauges, Number keys – Robinair ACR2005 Air Conditioning and Refrigerant Service Solution User Manual

Page 11: Up/down and left/right arrow keys

Advertising
background image

9

ACR2005 Refrigerant Service Solution

High-Side
Pressure Indicating
Needle (black)

High-Side
Follower
Needle (red)

(adjust so red
needle rests above
the black needle)

Low-Side
Pressure Indicating
Needle (black)

PRESSURE GAUGES

Both the high- and low-side gauges are equipped with red “follower” needles to
show either the maximum or minimum pressure reached during operation.

The

“follower” is carried to the highest or lowest operating pressure, and stays there
when the regular (black) needle indicates other pressures.

1. The follower on the low-side gauge should be adjusted so it rests on the

bottom side of the black needle when the A/C system is not in operation.

2. The follower on the high-side gauge should be adjusted so it rests on the top

side of the black needle when the A/C system is not in operation.

When set up this way, the follower will be carried to the highest pressure or lowest
pressure registered by the individual gauge.

NUMBER KEYS

Use these keys to change the evacuation time, vacuum level, or recharge weight if
you want an amount different than the default shown on the display. These keys
are also used to enter other numeric values, such as your area’s elevation above
sea level.

UP/DOWN AND LEFT/RIGHT ARROW KEYS

Pressing the

UP/DOWN

and

RIGHT/LEFT

keys moves the cursor on the screen

in that direction (up, down, right, or left). In addition, during numeric
programming, pressing the

UP

arrow increases the number; pressing the

DOWN

arrow decreases the number.

HP

Low-Side
Follower
Needle (red)

(adjust so red needle
rests below the black
needle)

Set U

Introduction

LP

Advertising