Initial setup, Warning, Initial setup instructions – Robinair ACR2005 Air Conditioning and Refrigerant Service Solution User Manual

Page 12

Advertising
background image

10

© 2004 Robinair, SPX Corporation

WARNING

Always wear eye protection when working with refrigerants.
Refrigerants can cause injury. Read and follow all warnings at the
beginning of this manual before operating this unit.

1. Unpack the ACR2005.

2. Attach the power cord to a 115V 60 Hz, 15 amp grounded outlet. Do not

use extension cords.

3. Turn the Power Switch to the ON position.

4. There is a brief initialization period of several seconds. You will be

prompted for the initial setup of the ACR2005. (This sequence occurs
ONLY during initial start up of a new ACR2005. Subsequent changes can
be made in the Setup Menu at any time).

5. Prompts are as follows:

A. Select Language—Press the

UP/DOWN

arrow to toggle between

selections. Press

ENTER

when your choice appears on the screen.

B. Select Units—English or Metric; toggle to your preferred selection, and
press

ENTER

.

C. Set Elevation above sea level for your location

±

500 feet. (Call your

area airport or library for your area’s elevation. On the Internet, go to
www.topozone.com and type your city name to view an elevation chart).

D. Calibrate the Pressure Transducer—Follow the prompts. Disconnect the
hoses from the ACR2005 during calibration.

E. Set Date and Time.

You will now be prompted to connect the correct hoses and accessories to the
ACR2005.

6. Open the accessory box packaged with the ACR2005.

INITIAL SETUP INSTRUCTIONS

IMPORTANT!
You can access
the Setup Menu
at any time to
change any of
these selections
by pressing
SETUP MENU.

The unit display
gives directions
and
explanations
based on
current vehicle/
service status.
Read and follow
these display
prompts at all
times!

CAUTION!

It is extremely important to follow these instructions! DO

NOT attach any hoses or accessories until prompted by the unit.
Incorrect setup and failure of the unit will result!

CAUTION!

R-134a systems have special fittings (per SAE specifications)

to avoid cross contamination with R-12 systems. Do not attempt to adapt
your unit for another refrigerant type—system failure will result!