VEHICLES WITH CONTAMINATED SYSTEMS

Before every recovery, the ACR2005 automatically samples the refrigerant in the
vehicle system. The operator cannot bypass this procedure. If a system fails the
purity level required, the ACR2005 tests a second time. In the event the system
fails a second time, the ACR2005 prompts you to disconnect the hoses from the
vehicle. Follow the on-screen prompts in order to clear out the ACR2005.

NOTE

: The ACR2005 must be disconnected from the vehicle before starting the

cleaning process. It is illegal to knowingly vent, or allow refrigerant to vent, to
the atmosphere.
Illegal venting will occur if the machine is left attached to the
vehicle.

Please refer to your shop’s policy, as well as current local, state, and federal laws,
for dealing with contaminated refrigerant.

Setup Instructions

POWER UP

1. Turn the Main Power Switch ON.

2. The display shows MAIN MENU and SELECT OPERATION when the

unit is ready for operation.