Securitron HHSR User Manual

Page 4

Advertising
background image

PN# 500-16600

Page 4

Rev. D, 07/11

Figure 3 - HHD, HVD, HHSL or HHSR-32

Figure 4 - HHD, HVD, HHSL or HHSR-62/82

Figure 5 - M62 or M82

On Aluminum Frame

(shown without stop)

NOTES FOR ALUMINUM FRAME DOOR
OPENINGS:
1) Blade type stops should be removed
from the frame to create access to the

housing cover attachment screws.
2) A spacer plate (not included) must be
installed under the mounting plate for
stops which are too narrow to provide a
sufficient mounting base. This will

create the clearance over the stop that
will allow access to the housing cover
attachment screws.
3) IN EITHER CASE AN OFFSET STRIKE
IS RECOMMENDED IN ORDER TO
POSITION THE STRIKE MOUNTING HOLE

AWAY FROM FEATURES INSIDE THE
DOOR RAIL THAT MAY CAUSE
INTERFERENCE WITH BOTH THE M62
AND M82 MODEL ASSEMBLIES.

PRIOR TO DRILLING STRIKE HOLES:
Double-check to verify that the markings for the strikes are in the required locations.
Please be aware that the location of the strike in relationship with the Magnalock is
important for the proper operation of the BondSTAT and the Door Position Sensor (if
equipped). SEE THE MAGNALOCK INSTALLATION INSTRUCTION MANUAL AND

PRODUCT TEMPLATE FOR COMPLETE STRIKE ALIGNMENT DETAILS AND INSTALLATION
INFORMATION.
Center punch and then drill 3/8” [9.5] diameter holes completely through the door at the
marked strike center locations. Then use the installation instruction manual, template and
hardware included with the Magnalock to properly install the strike plate.


3.2 HOUSING AND MAGNALOCKS
Remove and collect the hardware for reuse and then remove the cover from the full length
housing mounting plate.
In most cases the leading edge of the plate can be positioned away from the door at the
distance shown in Figures 3 & 4 (i.e. 3/8” [9.5] for M32 and 1/4” [6.3] for M62/M82).

However, in some cases it may be better to temporarily mount the Magnalocks to the mounting
plate. This will allow for an accurate positioning of the mounting plate when the Magnalock(s)
are placed directly against the strike(s) prior to marking or drilling the mounting hole locations.

Advertising