Rev. D, 07/11

NOTE: Mounting holes are configured to provide a flush mount up to a #14 X 4”
Flathead SMS/wood screw. These screws are not included, but may be utilized for an
even more secure assembly to a wooden door header.


To provide for the lock cable, a 3/8” [9.5] diameter wire feed through hole may be drilled
through the frame anywhere within the wire channel (slot) under each Magnalock mounting
area.
Using the provided 1/4-20 mounting screws and the flat washers originally included with the

Magnalock, install the Magnalock(s) to the mounting plate. Use a 3/16” hex wrench to tighten
the screws.
Pre-drill two (2) 9/64” [3.6] diameter pilot holes for the end cap mounting. These holes may be
drilled through the mounting plate for the TEK screws that hold the end cap in place.
Assemble the end caps to the mounting plate using the TEK screws provided.
Assemble the cover to the mounting plate using the collected (previously removed) hardware.


NOTE: The screws go to the front (door) side so that the tamper-proof sex bolts are to
the exposed side of the assembly as shown in Figure 8.