Document configuration settings – Securitron M680BDCX User Manual

Page 5

Advertising
background image

PN# 500-10560

Page 5

Rev. D, 07/12

SW2

DIP Switch:
PIR Enable and
Delay Selection

ENABLE PIR

Switch 5 ON

5 second delay

Switch 3 OFF (default)

10 second delay

Switch 3 ON

DIP Switch:
Auto Relock Timer
Enable and Delay
Selection
The Auto Relock Delay
Timer is disabled by
default. The delay can
be enabled by setting
Switch 4 to ON, and
then selecting a time
delay with Switch 1 and
Switch 2.

DISABLE Delay Timer

Switch 4 OFF (default)

ENABLE Delay Timer

Switch 4 ON

5 second delay

Switch1 OFF, Switch2 OFF

10 second delay

Switch1 OFF, Switch2 ON

20 second delay

Switch1 ON, Switch2 OFF

30 second delay

Switch1 ON, Switch2 ON

J1

Terminal Block 1
Tamper Switch

A 2-wire terminal block providing a SPDT contact that
changes state as determined by JP1 when the cover is
sensed to be removed by SW1.

J5

Terminal Block 5
Input Power

A 3-wire terminal block providing connection to the power
supply. Position 1 is a constant (+) for camera and PIR.
Position 2 is (+) for the lock power, position 3 is (-).

J6

Terminal Block 6
BondSTAT

A 3-wire terminal block providing a SPDT 1-Form C
contact that changes state when the BondSTAT bond is
interrupted.

J8

Terminal Block 8
Door Position Switch

A 6 wire terminal block providing:

(1-2) SPST contact determined by Jumper 3 based on
door position switch.
(3-4) SPST contact state change is determined by Jumper
2 based on REX activation.

(5-6) 2 position dry contact, closure disables PIR.

BNC Cable

BNC Connector for
Camera Signal

The included BNC cable can be routed through either side
of the maglock housing for connection to surveillance
system

3.

Document Configuration Settings

The Board Settings are now complete. Copy your settings onto the adhesive-backed Circuit Board Settings label
enclosed with the mounting hardware packet.


M670/M680 Settings

www.securitron.com

Jumper 4 (JP4) LED Enable

ENABLED DISABLED

Jumper 5 (JP5) LED SECURE Color

RED

GREEN

*Jumper 1 (JP1)Tamper Select Mode NC 1-2

NO 2-3

*Jumper 2 (JP2) Request to Exit Mode NO 1-2

NC 2-3

*Jumper 3 (JP3) Door Position Mode NC 1-2

NO 2-3

*(SW2) Auto Relock Delay

ENABLED DISABLED

*Delay (in seconds)

0 5 10 20 30

*available on select models

1-800-MAGLOCK




Important! Complete the label and affix
to the inside cover of your Magnalock

®

This information will be needed if the lock
needs to be serviced, replaced or inspected.

Advertising