Securitron DK-XB User Manual

Page 7

Advertising
background image

PN# 500-20300

Page 7

Rev. D, 06/11

APPENDIX A: COMMAND SUMMARY

WITH THE UNIT IN PROGRAM MODE (FAST YELLOW FLASH):

000 followed by 5-7 digits sets Program code
001 followed by 2-7 digits sets first User code
002 followed by 2-7 digits sets second User code
Additional User codes can be set up to the prefix 119 (total 119 User codes)

50 followed by 1 digit (0-9) sets system number
51 turns off system number reporting
52 enables

printer

53 disables

printer

60 followed by mmddyyhhmm (month, day, year, hour, minute) sets date and time in “US”

mode

61 followed by ddmmyyhhmm (day, month, year, hour, minute) sets date and time in

“international” mode

63 followed by 4 digits (0-7 only permitted) automatically assigns a set of user codes based on

the 4 digit “seed”

64 prints out all access codes active in memory
65 prints out a list of commands that have been selected to configure the unit
70 will sound beeper when door is open (except toggle mode). Echo and prompt beeps are

retained

71 will silence beeper at all times
72 will return beeper to factory set
73 will reverse light logic (red to echo, green to show door is open)
74 will return light logic to normal
751 will direct Hard code to programmable relay #1 for duress (entering Hard code releases

door and switches programmable relay #1)

752 will direct Hard code to programmable relay #2 for duress (entering Hard code releases

door and switches programmable relay #2)

761 will transfer alarm function to programmable relay #1 (16 wrong digits switches

programmable relay #1 as well as locking out keypad for 30 seconds)

762 will transfer alarm function to programmable relay #2 (16 wrong digits switches

programmable relay #2 as well as locking out keypad for 30 seconds)

771 will transfer light function to programmable relay #1 (relay #1 operates for 5 seconds when

any key is pressed)

772 will transfer light function to programmable relay #2 (relay #2 operates for 5 seconds when

any key is pressed)

781 will return programmable relay #1 to doorbell function.
782 will return programmable relay #2 to doorbell function.
79 is alternate code delete. Any valid code entered directly after the 79 command will be

deleted

80 assigns the HCD terminal to anti-tailgating
81 assigns the UCD terminal to anti-tailgating
82 assigns the HCD terminal to door prop alarm
83 assigns the UCD terminal to door prop alarm

(Note the door prop alarm function automatically includes anti-tailgating)

84 returns either HCD or UCD input to original (code disable) meaning

88 will erase all user codes (not Program or Hard code)
89 will return all functions (including timer) to factory set. Codes are unchanged.

Advertising
This manual is related to the following products: