Securitron DK-37 User Manual

Page 3

Advertising
background image

PN# 500-20750

Page 3

Rev. A, 11/13

Wiring Terminal Connections

DKC

Terminal

DK-37 Wiring Reference

Wire Color

+12V

Positive DC supply lead

Red

D0

Wiegand data zero

Green

D1

Wiegand data one

White

LED-G Green

light

Orange

LED-R Red

light

Brown

LED-Y Yellow

light

Blue

BUZ Audible

buzzer

Yellow

TAMP Tamper

indicator

Purple

( - )

Ground

Black

Feedback and Entry Overview
The DK-37 comes with green, yellow, and red LED indicators above the keypad. These three

indicator lights provide feedback during operation. When the DK-37 is in Wiegand mode there is
no yellow feedback light when connected to an access controller. The yellow light is designed to
work with the Securitron DKC Digital Keypad Controller. The three indicator lights are intended
for operation through an access controller either through a dry-contact connection to ground or
an open-collector driver. Please refer to the access controller for information about the meaning

of the indicator lights.

The table below is only for use with Securitron DKC

LED ACTION

MEANING

Red Light

Single Flash

 While in programming mode an error was made during

program entry; or

 A 5 second timeout occurred at any time during a

programming step.

Red Light

Double Flash

 While in programming mode a confirmation that a valid

program entry was made; or

 During normal operation the DK-37 was put into or taken

out of lockout mode.

Red Light

Continuous On

 During normal operation the relay is energized while the DK-

37 is in relay timer mode.

Red Light

Continuous On

 While in normal operation the DK-37 is in passage mode; or
 The DK-37 is in toggle mode and the relay is energized.

Yellow Light

Flashing

 In programming mode the LED flashes once per second

Yellow Light Continuous On

 While in normal operation this indicates that there are no

codes in memory.

Green Light

Single Flash

 Key press detected.

Green Light

Continuous On

 While in normal mode a 30-second lockout occurred after 16

wrong digits were entered; light turns off after lockout time.

Backlight Double

Flash

 While in normal mode a valid code was entered while the

DK-37 was in lockout mode.


The DK-37 is provided with a beeper that can be used to indicate when a button is pressed or

the relay is energized. The beeper functions are detailed in the table below and are valid for use
with the Securitron DKC.