Securitron DSB_Series User Manual

Page 3

Advertising
background image

PN# 500-22700

Page 2

Rev. F, 03/11

Fasteners for metal doors (aluminum frame and hollow steel) are included. For through door

mounting please call Securitron for a no-charge DSB-TDM kit. Note that US standard or metric

fasteners are supplied depending on the version of the bar which was ordered. (The metric
version part number for a DSB series bar will include the suffix “M”).

5. RECOMMENDED TOOLS

Bubble Level

Power Drill

Hammer Pliers,

Vise-grip

Center Punch
Wrenches:

1/2” Box-end (or Adjustable Wrench)

Screwdrivers:

#1 and #2 Phillips, 1/8” [3mm] Flat

Drill Bits:

3/8” [9.5mm], 11/16” [17.5mm]

Standard DSB Hex Wrench: 3/16”

Metric DSB Hex Wrench: 5mm

6. INSTALLATION INSTRUCTIONS
AS THE DSB IS NORMALLY USED TO ALLOW EGRESS ON AN ELECTRICALLY SECURED

DOOR, ENSURE THAT ALL APPLICABLE BUILDING AND FIRE CODES ARE BEING

FOLLOWED. VERIFY INSTALLATION WITH LOCAL BUILDING AND/OR FIRE

PREVENTION CODES AND REGULATIONS.


THE DUAL SENSE BAR MAY NOT BE USED ON A FIRE RATED DOOR THAT REQUIRES A

FIRE RATED LATCH! THE DSB HAS NO LATCH. IN SOME INSTANCES HOWEVER, FIRE

DOORS ARE ALLOWED ON OPENINGS WHERE A FIRE RATED BARRIER IS NOT

REQUIRED. USE OF THE DSB SHOULD ALWAYS BE VERIFIED AND APPROVED

THROUGH LOCAL BUILDING CODE AND/OR FIRE PREVENTION DEPARTMENTS.

6.1. BAR POSITIONING AND MOUNTING HOLE MARKING
Using a #1 Phillips screwdriver, remove the screws and the end caps from both ends of the bar.

Verify that the bar is the correct length for the door. If it appears that the bar is longer than it

should be for the door, see Section 6.6 for cutting instructions. Take note of which end has the

main (touch sense) PC board in it, this end has a ring terminal connecting the PCB to the bar

profile. This is the end that should be mounted on the hinge side for the most convenient wire

exit from the door.


The DSB, as shipped from the factory, is assembled with shipping clips at each end that

temporarily hold the bar together while positioning and mounting the bar to the door (see

Figure 2).

FOR EASE OF INSTALLATION, DO NOT REMOVE THE SHIPPING CLIPS UNTIL AFTER THE

BAR HAS BEEN MOUNTED.

Figure 2

For best results, the assembled DSB itself may be used as a template to locate and mark the

mounting holes. When positioning the bar for marking the holes, ensure the following:

The bar is positioned at the correct height from the floor (see Figure 3).

Generally, US Building Codes require that the bar be located between 30 inches [762mm] and

44 inches [1118mm] from the bottom of the door.