Gilderfluke&Co Ir-Passive Instructions User Manual

Settings, Jumpers, Adjustment

Advertising
background image

Settings

Jumpers:

The ‘NC/NO’ jumper is

normally removed so that
the sensor is operated in
the ‘Normally Open’ (‘NO’
mode. When the sensor is
tripped, the ‘Alarm’ outputs
are closed. When it is idle,
the ‘Alarm’ output is open.
On the GilderGear that the
IR-Passive will be trigger-
ing, set the show or sound
to start on the ‘closing’
edge, and set it for ‘un-
steppable’ so it isn;’t retrig-
gered each time the sensor
trips.

The ‘PC’ jumper is for

selecting between two or
three ‘Pulse Counts’ before
the sensor trips. With the
jumper in place, the sensor
is slightly more sensitive
than when you have the
jumper removed.

The ‘LED’ jumper dis-

ables the red indicator LED
on the IR-Passive when it is
removed.

Adjustment:

If your Ir-Passive has a

‘Walk Test’ (‘WT’) jumper,
temporarily remove it to
test the sensitivity of the Ir-
Passive.

I f t h e I r - P a s s i v e i s

mounted on a wall facing
horizontally, you can adjust
the minimum height of
objects it can see by loos-
ening the ‘Fixing Screw’
and sliding the PCB up-
wards and downwards. By
sliding the PCB down-
wards, it will shoot over
small moving objects like
children and other small
animals.

Fifteen percent of all Americans spend an average of ten minutes

each day searching for their television remote controls.

- Eli the Mule, CEM

“I am proud of the fact that I never invented weapons to kill”

- Thomas Edison

ilderAppNote

A p p l i c a t i o n H i n t s f r o m t h e W o r l d o f G i l d e r f l u k e & C o .

GilderHeadquarters • 205 South Flower Street • Burbank, California 91502-2102 • 818/840-9484 • 800/776-5972 • FAX: 818/840-9485

1

GilderAppNote • Monday, November 29, 2010

Wiring the Ir-Passive Motion Detector

The Ir-Passive requires a 9 to 24 vdc power supply to run. This can be an independent power

supply, or power can be ‘borrowed’ from the GilderGear or some other equipment in your installa-
tion. The Ir-Passive may be damaged by supply voltages over 24 vdc, so do not use an unregulated
24 vdc power supply.

The Ir-Passive provides a ‘dry’ switch closure to the GilderGear it is controlling. All GilderGear has

optically isolated inputs, and most will need you to supply a voltage in order to trigger the input.
You can borrow this from the voltage that is used to run the Ir-Passive:

Br-miniBrick8,
Br-miniBrick4,
Sd-10, Sd-25,
Sd-50, etc.

n/c

n/c

- 9-24 vdc + N/O switch

For attaching to inputs that have the option of using ‘internal’ power, the contacts can be wired

directly to the inputs:

1/4 J6 on
Br-Brain4, Sd-50,
etc., set for
'internal power'

n/c

n/c

- 9-24 vdc + N/O switch

The normally closed ‘Tamper Switch’ contacts are not normally used. They open when the Ir-

Passive’s cover is opened.