cables. Place the selected fully charged battery with
full electrolyte in battery tray and secure with battery

hold down strap.

Before connecting battery cables to battery,
complete the following steps:


Battery cables are factory connected at the generator
points (red engine starter motor (positive) cable and

black ground (negative) cable). Electrician should
connect the red battery cable (from engine starter
solenoid point) to battery post shown with “positive”,
POS, or (+) indicator. Connect the black battery

cables (from frame ground) to the battery negative
post. NOTE: Both positive and negative battery

cables have protective “boots” that enclose the cable
connections to battery posts. Also, positive battery

cable is secured, so that, if cut or disconnected in any
way, positive cable won’t touch metal door.

Dielectric grease should be used on battery lugs or
posts to help in the prevention of normal corrosion.

Damage will result to generator controls, if battery
cables are made in reverse connections.

Inspect, clean, or re-grease battery connections ever

60-90 days.

In cold climate areas, where temperatures normally

reach 10º F (-12º C) or colder, an optional battery
wrap-around heater, controlled by thermostat,
should be used, for increased battery power.

This generator is equipped with an automatic “float
type” 3-stage (bulk, absorption, and float) battery
charger, energized by utility power, to maintain full

battery power while on standby (non-running)
condition. CAUTION: This charger can not recharge

a fully discharged or defective battery.

Do not dispose of battery in a fire. The

battery is capable of exploding and
spewing electrolyte in several directions.


Do not open up a battery. It has

electrolyte and is harmful to the skin and
eyes, and is toxic.


Battery electrolyte is electrically

conductive and corrosive.

The high voltage access panels should only
be removed by experienced licensed
electricians, repair and service personnel,

and installers.

Electrical shock from mishandled

battery.

Toxic fumes from battery or engine

exhaust may be inhaled.

Hot surfaces may cause severe burns.

Explosions from battery or dry fuel

fumes being ignited by careless smoking

or sparks from mishandled tools.

All hinged or bolted panel contains access
to A-C and D-C dangerous high voltage
electricity. These voltages can cause a

fatal electric shock and will cause sudden illness,
dizziness, and incoherent actions. Only

experienced licensed electricians and authorized
service technicians should have access behind
closed and locked housing doors.

BATTERY SELECTION & INSTALLATION

The 12 VDC battery is not furnished with the standby

generator set. The generator can be installed in a
wide range of temperatures and climate conditions.
As climates get colder, batteries loose their ability to

produce required power. Therefore, battery size
must be increased. Installer must provide proper
battery size, depending on environment.

Climates that reach to a low of 20º F (-6.7º C) can
achieve good generator operation with a 12 VDC,
heavy duty battery. Climates that reach below this
temperature line should have a 10-20% increase in

CCA rating for a 12 VDC battery. See Battery Chart
on page 17. (See Figure 8)

CAUTION: All 12 VDC batteries will loose a certain

percent of their charge while in storage. It is very
important to test the battery voltage before it is
installed in generator and taken to jobsite. A fully

charged battery must test at 12.5 – 13.0 volts DC.
Also, the correct battery must have lug terminals to
match lug battery cables, for a bolt-together
connection. When replacing batteries, use the
same number and the following type batteries:
Sealed

type:lead-acid

(1) 20-60 KW 1800 RPM sets 650 C.C.A. or 55 amp/hour
(1) 80-140 KW 1800 RPM sets 710 C.C.A. or 65 amp/hour

This generator is equipped with a corrosion resistant

battery tray, a battery hold down strap and battery

WARNING

DANGER

NOTICE