Operation – IAI America RCA-E User Manual

Page 22

Advertising
background image

P. 19

8-4-3 The Relationship Between the Push Power During Stop and Current Restriction Value

When executing the push mode, place the current restriction value as a “% of max” column into the “push”
column of the position data table. Determine the current restriction (in %) using the tables below. The diagram
below shows the relationship between the current restriction value and push power for each actuator type.

Caution:
Please be aware that the push power is a standard, and is not guaranteed. When the push power is too small,
push malfunction may occur due to driven resistance, so please be careful. The maximum amount of the current
restriction value is listed in the table below:

Current restriction value

Low Speed Type

Middle Speed Type

High Speed Type

S5

40% or less

40% or less

40% or less

S6

50% or less

50% or less

50% or less

Lead

Type

Lead

Type

Low Speed Type

Middle Speed Type

High Speed Type

Push power (kgf)

S6 Type

20.0

15.0

10.0

5.0

0.0

S5 Type

10%

20%

30%

40%

Push power (kgf)

20.0

15.0

10.0

5.0

0.0

25.0

Low
Speed
Type

Medium
Speed
Type

High
Speed
Type

Low
Speed
Type

Medium
Speed
Type

High
Speed
Type

8. Operation

Current restriction value

10% 20%

30% 40% 50%

Advertising