9. Message Area

In the message screen, content during error and warning will be displayed.

* Refers to the Teaching Box

9-1 Warning Label Error

Warning message is cleared by recovery procedure as follows:

Release operation:

1.

First, confirm the cause of the warning and resolve the problem.

2.

Press down BEGIN/END Key.

Warning is probably due to the following possibilities:

• RS485 communication abnormality
• Teaching Pendant operational mistake

Cause:

1)

RS 485 communication related abnormality

For example, when move command is delivered by PIO signal from teaching while communicating to
other devices (PLC), “075h” will occur.

2)

Influence by foreign noise or connections is not properly installed.
The teaching pendant and RC controller execute packet communication at all times. At this time,
when data changes due to noise, the RC controller will determine that it is incorrect data and will
reject the data.

Solution:

1)

Confirm the above causes. In the case of frequent warning occurences, please remove the signal cable
and power line.

9-2 Teaching Pendant Message Label Error

Teaching Pendant operational mistake:

When you attempt to input an incorrect value, the message label error will occur.
Code No: 112h, 113h, 114h, 118h, 11Eh, 11Fh • • • Keypad input value is incorrect.

Code No.

Error Label

Error Reset

Reference

000~07F

Controller Warning

Yes

Controller rejects command

080-0FF

Controller Error

Yes

Error inside the controller

100~1FF

TB* Message

Yes

Input error, guide message, etc.

200~2FF

TB* Movement Release

Yes

Movement continuation impossible

300~3FF

TV Cold Start Error

No

TB Power install or reconnect are not necessary.