9. Message Area

Code

Error Description

Common Solutions

05A

Transmission Error

Abnormal Communication, Check for noise. Inspect all serial ports and cables involved.

05B

Transmission Framing Error

05D

Start Text Error

05E

End Text Error

07F

BCC Error

061

FNCCHR, W Address Error

Serial string needs to be formated correctly.

062

1 Operand Error

Incorrect Data Command (possibly an operation not allowed with the controller type).

063

2 Operand Error

Incorrect Data Command (possibly an operation not allowed with the controller type).
In case of another placed controller, there could be an initialization of rotation numbers

which surpasses 200rpm against the SW7-ON, SW8-off against the controller.

064

3 Operand Error

Incorrect Data Command Rejection (possibly an operation not allowed with the controller type).

067

BCC Error

Incorrect Data Command Rejection (characters other than either 0~9 or A~F are included).

070

RUN-OFF, Transfer Command

Incompatible Command Rejection
(possibly due to External PIO command).

071

No homing, PTP

073

Servo ON, Error Reset

074

Communication Error

075

During homing, movement
command

Attempted move while homing.

0B0

Bank 30 Error (Parameter)

Execute a common parameter edit or initialize the controller.

0B1

Bank 31 Error (Point)

1. Cycle power to controller

2. Possibly, parameters need to be set correctly.

9-3 Controller Error

An alarm detected from the controller side can be displayed. This is a serious error due to abnormality related to servo
control and electricity. Please read though the RC Controller operating manual carefully for error compliance.

Code No:

0B0h, 0B1h, 0B8h, 0B9h, 0BBh, 0BCh, 0BDh, 0BEh
0C0h, 0C1h, 0D0h, 0D1h, 0D8h, 0E0h, 0E8h, 0E9h, 0EAh, 0F8h