3. Installation and Noise Elimination


Pay due attention to the installation environment of the controller.


3.1 Installation

Environment


(1) When installing and wiring the controller, do not block the cooling ventilation holes. (Insufficient ventilation

will not only prevent the controller from demonstrating its full performance, but it may also cause
breakdown.)

(2) Prevent foreign matter from entering the controller through the ventilation holes. Since the enclosure of the

controller is not dustproof or waterproof (oilproof), avoid using the controller in a place subject to significant
dust, oil mist or splashes of cutting fluid.

(3) Do not expose the controller to direct sunlight or radiating heat from a large heat source such as a heat

treatment furnace.

(4) Use the controller in an environment free from corrosive or inflammable gases, under a temperature of 0 to

40

C and humidity of 85% or less (non-condensing).

(5) Use the controller in an environment where it will not receive any external vibration or shock.
(6) Prevent electrical noise from entering the controller or its cables.

3.2 Power

Supply


The power supply specification is 24 VDC

 10%.

(Supply current: 2 A max.)

3.3

Noise Elimination and Grounding


This section explains how to eliminate noise in the use of the controller.

(1)

Wiring and power supply

[1] Provide a dedicated class D grounding using a wire with a size of 2.0 to 5.5 mm

2

or larger.

















Class D grounding

Good

Avoid this grounding method.

Controller

Other

equipment

Controller

Other

equipment

Use a cable of a
maximum possible
size and keep the
wiring length at a
minimum.

Metal frame