47

5.1.2

Signal Assignment Table for Respective PIO Patterns


The same signal may be assigned to a different pin number depending on the PIO pattern. Therefore, when
creating a PLC sequence or wiring the signals, refer to this table to ensure each signal is assigned correctly.
When “4: [Teaching]” is selected, the meaning of each pin number will vary depending on the mode. Accordingly,
also pay due attention to when mode switching will occur.

Parameter No. 25 setting

Pin

No.

Category Wire

color

0 1 2 3 4 5

1A +24V

Upper stage

Brown - 1

P24

2A

0V

Red - 1

N

3A

Orange - 1

CSTR

PC1

PC1

PC1

PC1

ST0

4A

Yellow - 1

PC1

PC2

PC2

PC2

PC2

ST1

5A

Green - 1

PC2

PC4

PC4

PC4

PC4

ST2

6A

Blue - 1

PC4

PC8

PC8

PC8

PC8

ST3

7A

Purple - 1

PC8

-

PC16

-

MODE

-

8A

Gray - 1

-

*STP

PC32

*STP

*STP/JOG +

*STP

9A

White - 1

-

CSTR

CSTR

CSTR

CSTR/PWRT

-

10A

Black - 1

*STP

HOME

HOME

HOME

HOME

-

11A

Brown - 2

-

SON

*STP

SON

SON

-

12A

Input

Red - 2

-

RES

RES

RES

RES/JOG –

RES

13A

Orange - 2

(Not used)

1B

Lower

stage

Yellow - 2

(Not used)

2B

Green - 2

(Not used)

3B

Blue - 2

PM1

PM1

PM1

PM1

PM1

PE0

4B

Purple - 2

PM2

PM2

PM2

PM2

PM2

PE1

5B

Gray - 2

PM4

PM4

PM4

PM4

PM4

PE2

6B

White - 2

PM8

PM8

PM8

PM8

PM8

PE3

7B

Black - 2

PEND

ZONE1

PM16

ZONE1

MODES

ZONE1

8B

Brown - 3

HEND

MOVE

PM32

ZONE2

MOVE

-

9B

Red - 3

ZONE1

PEND

PEND

PEND

PEND/WEND

PEND

10B

Orange - 3

*ALM

HEND

HEND

HEND

HEND

HEND

11B

Yellow - 3

*EMGS

12B

Green - 3

-

SRDY

MOVE

SRDY

SRDY

-

13B

Output

Blue - 3

-

*ALM

*ALM

*ALM

*ALM

*ALM

Note:

[1] The signals indicated by * in the table (*ALM, *STP and *EMGS) are based on the negative

logic, meaning that they remain ON in normal conditions of use.

[2] Insulate the pins indicated “Not used” (13A, 1B and 2B) without connecting anything.
[3] The NPN and PNP specifications use the same power line configuration, so there is no need to

reverse the power signal assignments for a PNP controller.

[4] *EMGS (emergency-stop state) assigned to pin No. 11B is enabled on a “built-in cutoff relay”

controller.